![]() |
Error hlįsenia |
![]() |
![]() |
Zoznam chybovżch a diagnostickżch hlįsenķ BIOSov
AMI BIOS Text Error
hlįsenia
Hlįsenia | Explanation |
Bad PnP Serial ID Checksum | The Serial ID checksum of a PnP card is invalid |
Floppy Disk Controller Resource Conflict | The floppy drive controller had requested a resource that is already in use |
NVRAM Checksum Error - NVRAM Cleared | The extended system configuration data (ESCD) was reinitialized because of an NVRAM checksum error. Clear CMOS and ESCD RAM and reboot |
NVRAM Cleared By Jumper | The Clear CMOS jumper has been moved to the Clear position. CMOS RAM and ESCD have been cleared |
NVRAM Data Invalid - NVRAM Cleared | Invalid data found in the ESCD, which might mean that you have changed devices in the system. When this message is displayed, the BIOS has already rewritten the ESCD with current configuration data |
Parallel Port Resource Conflict | The parallel port requested a resource that is already in use |
PCI Error Log is Full | More than 15 PCI conflict errors have been detected and no additional PCI errors can be logged |
PCI I/O Port Conflict | Two devices requested the same I/O address, resulting in a conflict |
PCI IRQ Conflict | Two devices requested the same IRQ, resulting in a conflict |
PCI Memory Conflict | Two devices requested the same memory resource, resulting in a conflict |
Primary Boot Device Not Found | Two designated primary boot device (hard disk, floppy disk drive, CD-ROM drive) could not be found |
Primary IDE Controller Resource Conflict | The primary IDE controller has requested a resource that is already in use |
Primary Input Device Not Found | The designated primary input device (keyboard, mouse, or other device if input is redirected) could not be found |
Secondary IDE Controller Resource Conflict | The secondary IDE controller has requested a resource that is already in use |
Serial Port 1 Resource Conflict | Serial port 1 has requested a resource that is already in use |
Serial Port 2 Resource Conflict | Serial port 2 has requested a resource that is already in use |
Static Device Resource Conflict | A card that is not Plug-and-Play ISA has requested a resource that is already in use |
System Board Device Resource Conflict | A card that is not Plug-and-Play ISA has requested a resource that is already in use |
A20 Error | Gate A20 on the keyboard controller is not working |
Address line Short | Error in the address decoding circuitry on the motherboard |
CMOS Battery State Low | The battery power is low; replace the battery |
CMOS Checksum Invalid | After CMOS RAM values are saved, a checksum value is generated for error checking. The previous value is different from the current value |
Run Setup | CMOS system options not set. The values stored in CMOS RAM are either corrupt or nonexistent. Run Setup |
CMOS Display Type Mismatch | The video type in CMOS RAM does not match the type detected by the BIOS. Run Setup |
CMOS Memory Size Mismatch | The amount of memory on the motherboard is different from the amount indicated in CMOS RAM. Run Setup |
CMOS Time and Date Not Set | run Setup to set the time and date in the CMOS RAM |
Diskette Boot Failure | The boot disk in drive A: is corrupt. It cannot be used to boot the system. Use another boot disk and follow the screen instructions |
DMA Error | Error in the DMA controller |
DMA #1 Error | Error in the first DMA controller |
DMA #2 Error | Error in the second DMA controller |
FDD Controller Failure | The BIOS cannot communicate with the floppy disk drive controller. Check all appropriate cables and connections |
HDD Controller Failure | The BIOS cannot communicate with the hard disk drive controller. Check all appropriate cables and connections |
Insert Bootable Media | The BIOS cannot find a bootable medium. Insert a bootable floppy disk or CD-ROM |
INTR #1 Error | Interrupt controller 1 failed POST |
INTR #2 Error | Interrupt controller 2 failed POST |
Invalid Boot Diskette | The BIOS can read the disk in floppy drive A:, but cannot boot the system from it. Use another boot disk |
KB/Interface Error | There is an error in the keyboard connector |
Keyboard Error | There is a timing problem with the keyboard |
Keyboard Stuck Key Detected | A stuck keyboard key was detected |
Off Board Parity Error | Parity error in memory installed in an expansion slot. The format is: OFF BOARD PARITY ERROR ADDR (HEX) = (XXXX), where XXXX is the hex address where the error occurred |
On Board Parity Error | Parity error in memory installed on the motherboard. The format is: ON BOARD PARITY ERROR ADDR (HEX) = (XXXX), where XXXX is the hex address where the error occurred |
Parity Error | Parity error in system memory at an unknown address |
System halted | An error caused the computer to halt |
Timer Channel 2 Error | There is an error in counter/timer 2 |
Uncorrectable ECC Error | An uncorrectable ECC memory error was detected |
Undetermined NMI | An undetermined NMI was detected |
Memory parity Error at xxxxx | Memory failed. If the memory location can be determined, it is displayed as xxxxx. If not, the message is Memory Parity Error ????. |
I/O Card Parity Error at xxxxx | An expansion card failed. If the address can be determined, it is displayed as xxxxx. if not, the message is I/O Card Parity error ???? |
DMA Bus Timeout | A device has driven the bus signal for more than 7.8 microseconds |
AMI BIOS - Pre BIOS Feb. 1991:
Hlįsenie |
Popis |
NMI Disable | NMI interrupt line to the CPU is disabled by setting bit 7 I?O port 70h (CMOS) |
Power On Delay | Once the keyboard controller gets power, it sets the hard and soft reset bits. Check the keyboard controller or clock generator if a failure occurs |
Initialize Chipsets | Check the BIOS, CLOCK and chipsets |
Reset Determination | The BIOS reads the bits in the keyboard controller to see if a hard or soft reset is required (a soft reset will not test memory above 64K). Failure could be the BIOS or keyboard controller |
ROM BIOS Checksum | The BIOS performs a checksum on itself and adds a preset factory value that should make it equal to 00. If a failure occurs, check the BIOS chips |
Keyboard Test | A command is sent to the 8042 keyboard controller which performs a test and sets a buffer space for commands. After the buffer is defined the BIOS sends a command byte, writes data to the buffer, checks the high order bits of the internal keyboard controller and issues a No Operation (NOP) command |
CMOS | Shutdown byte in CMOS RAM offset 0F is tested, the BIOS checksum calculated and diagnostic byte 0E updated before the CMOS RAM area is initialized and updated for date and time. Check the RTC and CMOS chip or battery if a failure occurs |
DMA (8237) and PIC (8259) Disable | The DMA and Programmable Interrupt Controller are disabled before the POST proceeds and further. Check the 8237 or 8259 chips if a failure occurs |
Video Disable | The video controller is disabled and port B initialized. Check the video adapter if a failure occurs |
Chipset Initialized and Memory Detected | Memory addressed in 64K blocks. Failure would be in the chipset. If all memory is not seen, failure could be in a chip in the block after the last one seen |
PIT Test | The timing functions of the 8254 Programmable Interrupt Timer are tested. The PIT and RTC chips normally cause errors here |
Memory Refresh | PIT's ability to refresh memory is tested. If an XT, DMA controller #1 handles this. Failure is normally the PIT (8254) in AT's or the 8237, DMA #1, in XT's |
Address Line | Test the address lines in the first 64K of RAM. If a failure occurs, an address line may be the problem |
Base 64K | Data patterns are written to the first 64K of RAM, unless there is a bad RAM chip in which case you will get a failure |
Chipset Initialization | The PIT, PIC and DMA controllers are initialized |
Set Interrupt Table | Interrupt vector table used by PIC is installed in low memory, the first 2K |
8042 Keyboard Controller Check | The BIOS reads the buffer area in the keyboard controller I/O port 60. Failure here is normally the keyboard controller |
Video Tests | The type of video adapter is checked for, then a series of tests are performed on the adapter and monitor |
BIOS Data Area | The vector table is checked for proper operation and video memory verified before protected mode tests are entered into. This is done so that any errors found are displayed on the monitor |
Protected Mode Tests | Perform reads and writes to all memory locations below 1MB. Failure at this point indicate a bad RAM chip, the 8042 Keyboard Controller or a data line |
DMA Chips | The DMA registers are tested using a data pattern |
Final Initialization | these differ with each version. Typically, the floppy and hard drives are tested and initialized and a check is made for serial and parallel devices. The information gathered is then compared against the contents of the CMOS and you will see the results of any failures on the monitor |
BOOT | The BIOS hands over control to the Int 19 bootloader. This is where you would see error messages such as non-system disk |
AWARD
BIOS Text Error hlįsenia:
Hlįsenia |
Popis |
BIOS ROM checksum error - System halted | The checksum of the BIOS code in the BIOS chip is incorrect, indicating the BIOS code may have become corrupt. Replace the BIOS |
CMOS battery failed | CMOS battery is no longer functional. Replace the battery |
CMOS checksum error - Defaults loaded | Checksum of CMOS is incorrect, so the system loads the default values. A checksum error may indicate that CMOS has become corrupt. This error might have been caused by a weak battery |
CMOS CHECKSUM ERROR DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER | Checksum of CMOS is incorrect. This can indicate that CMOS has become corrupt. This error may have been caused by a weak CMOS battery |
CPU at nnn | Displays the running speed of the CPU |
DISKETTE DRIVES OR TYPES MISMATCH ERROR - RUN SETUP | Type of diskette drive installed in the system is different from the CMOS definition. Run Setup to reconfigure the drive type correctly |
Display switch is set incorrectly | The display switch on the motherboard can be set to either monochrome or color. This message indicates the switch is set to a different setting than indicated in Setup. Determine which setting is correct and then either turn off the system and change the jumper or enter Setup and change the video selector |
DISPLAY TYPE HAS CHANGED SINCE LAST BOOT | Since last powering off the system, the display adapter has been changed. You must configure the system for the new display type |
EISA Configuration Checksum Error | The EISA nonvolatile RAM checksum is incorrect or cannot correctly read the EISA slot. This can indicate either the EISA nonvolatile memory has become corrupted or the slot has been configured incorrectly. Also, be sure the card in installed firmly in the slot |
EISA Configuration Is Not Complete | The slot configuration information stored in the EISA nonvolatile memory is incomplete |
ERROR ENCOUNTERED INITIALIZING HARD DRIVE | Hard drive cannot be initialized. Be sure the adapter is installed correctly and all cables are correctly and firmly attached. Also be sure the correct hard drive type is selected in Setup |
ERROR INITIALIZING HARD DISK CONTROLLER | Cannot initialize controller. Make sure the card is correctly and firmly installed in the bus. Be sure the correct hard drive type is installed in Setup. Also check to see if any jumper needs to be set correctly on the hard drive |
FLOPPY DISK CONTROLLER ERROR OR NO CONTROLLER PRESENT | Cannot find or initialize the floppy disk controller. make sure the controller is installed correctly and firmly. If there are no floppy drives installed, be sure the Diskette Drive selection in Setup is set to None |
Floppy disk(s) fail | Cannot find or initialize the floppy drive controller or the drive. make sure the controller is installed correctly. If no floppy drives are installed, be sure the Diskette Drive selection in Setup is set to None or Auto |
HARD DISK initializing | Please wait for a moment... Some hard drives require some extra time to initialize |
HARD DISK INSTALL FAILURE | Cannot find or initialize the hard drive controller or the drive. Make sure the controller is installed correctly. If no hard drives are installed, be sure the Hard Drive selection in Setup is set to None |
Hard disk(s) diagnosis fail | The system may run specific disk diagnostic routines. this message appears if one or more hard disks return an error when the diagnostics run |
Invalid EISA Configuration | The nonvolatile memory containing EISA configuration information was programmed incorrectly or has become corrupt. Rerun EISA configuration utility to correctly program the memory |
Keyboard error or no keyboard present | Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys are being pressed during the boot. If you are purposely configuring the system without a keyboard, set the error halt condition in Setup to HALT ON ALL, BUT KEYBOARD. This will cause the BIOS to ignore the missing keyboard and continue the boot |
Keyboard is locked out - Unlock the key | This message usually indicates that one or more keys have been pressed during the keyboard tests. Be sure no objects are resting on the keyboard |
Memory Address Error at... | Indicates a memory address error at a specific location. You can use this location along with the memory map for your system to find and replace the bad memory chips |
Memory parity Error at... | Indicates a memory parity error at a specific location. You can use this location along with the memory map for your system to find and replace the bad memory chips. |
MEMORY SIZE HAS CHANGED SINCE LAST BOOT | Memory has been added or removed since the last boot. In EISA mode, use configuration utility to reconfigure the memory configuration. In ISA mode,enter Setup and enter the new memory size in the memory field |
Memory Test | The message displays during a full memory test, counting down the memory areas being tested |
Memory Test Fail | If POST detects an error during memory testing, additional information appears giving specifics about the type and location of the memory error |
Memory Verify Error at... | Indicates an error verifying a value already written to memory. Use the location along with your system's memory map to locate the bad chip |
No boot device was found | This could mean that either a boot device was not detected or the drive does not contain proper system boot files. Insert a system disk into drive A: and press Enter. If you assumed the system would boot from the hard drive, make sure the controller is inserted correctly and all cables are properly attached. Also be sure the disk is formatted as a boot device. Then reboot the system |
OFFENDING ADDRESS NOT FOUND | The message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY ERROR messages when the segment that has caused the problem cannot be isolated |
OFFENDING SEGMENT: | This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY ERROR messages when the segment that has caused the problem has been isolated |
Override enabled - Defaults loaded | If the system cannot boot using the current CMOS configuration, the BIOS can override the current configuration with a set of BIOS defaults designed for the most stable, minimal-performance system operations |
PRESS A KEY TO REBOOT | This will be displayed at the bottom of the screen when an error occurs that requires you to reboot. Press any key to reboot the system |
Press ESC to skip memory test | You can press ESC to skip the full memory test |
PRESS F1 TO DISABLE NMI, F2 TO REBOOT | When BIOS detects a non-maskable interrupt condition during boot, this will allow you to disable the NMI and continue to boot; or you can reboot the system with the NMI enabled |
Press TAB to show POST screen | System OEM's may replace the Award BIOS POST display with their own proprietary display. Including this message in the OEM display permits the operator to switch between the OEM display |
Primary master hard disk fail | POST detects an error in the primary master IDE hard drive |
Primary slave hard disk fail | POST detects an error in the secondary master IDE hard drive |
RAM PARITY ERROR - CHECKING FOR SEGMENT... | Indicates a parity error in RAM |
Resuming from disk, Press TAB to show POST screen | Award offers a save-a-disk feature for notebook computers. This message may appear when the operator restarts the system after a save-to-disk shutdown. See the Press Tab...message earlier for a description of this feature |
Secondary master hard disk fail | POST detects an error in the secondary master IDE hard drive |
Secondary slave hard disk fail | POST detects an error in the secondary slave IDE hard drive |
Should Be Empty But EISA Board Found | A valid board ID was found in a slot that was configured as having no board ID |
Should Have EISA Board But Not Found | The board installed is not responding to the ID request, or no board ID has been found in the indicated slot |
Slot Not Empty | Indicates that a slot designated as empty by the EISA configuration utility actually contains a board |
SYSTEM HALTED. (CTRL-ALT-DEL) TO REBOOT... | Indicates the present boot attempt has been aborted and the system must be rebooted. Press and hold down the Ctrl and Alt keys and press Del |
Wrong Board In Slot | The board ID does not match the ID stored in the EISA nonvolatile memory |
Kód | Popis |
0101-xx | CPU test failure |
0102-xx | Coprocessor test failure |
0103-xx | DMA controller failure |
0104-xx | Interrupt controller failed |
0105-xx | Port error |
0106-xx | Keyboard controller self test failed |
0107-xx | CMOS RAM test failed |
0108-xx | CMOS interrupt test failed |
0109-xx | CMOS clock test failed |
0110-xx | Programmable interrupt timer failure |
0113-01 | Protected mode test failed |
0114-01 | Speaker test failed |
Memory Test Error kódy
Kód | Popis |
0200-xx | Memory machine ID test failure |
0202-xx | Memory system ROM checksum failure |
0203-xx | Memory read/write test failure |
0204-xx | Memory address test failure |
0205-xxx | Memory walking 1's test failure |
0209-xxx | RAM long test failure |
0211-xx | Random pattern test failure |
0212-xxx | Cache test failure |
0214-xx | Noise test failure |
0215-xx | Random address test failure |
Keyboard Test Error kódy
Kód | Popis |
0300-xx | Keyboard ID test failure |
0301-xx | Keyboard self test/interface test failure |
0302-xx | Individual key test failure |
0304-xx | Keyboard repeat test failure |
Parallel Printer Test Error kódy
Kód | Popis |
0401-xx | Printer failure or not connected |
0402-xx | Printer port test failure |
0403-xx | Printer pattern test failure |
Diskette Drive Test Error kódy
Kód | Popis |
0600-xx | Diskette ID drive types test failure |
0601-xx | Diskette format failure |
0602-xx | Diskette read test failure |
0603-xx | Diskette write, read, compare test failure |
0604-xx | Diskette random seek test failure |
0605-xx | Diskette ID media test failure |
0606-xx | Diskette speed test failure |
0607-xx | Diskette change line test failure |
Serial Port Test Error kódy
Kód | Popis |
1101-xx | Serial port test failed |
Modem Communications Test Error kódy
Kód | Popis |
1201-xx | Modem internal test failure |
1203-xx | Modem external termination test failure |
1204-xx | Modem auto originate test failure |
1205-xx | Modem auto answer test failure |
1210-xx | Modem direct connect test failure |
Hard Drive Test Error kódy
Kód | Popis |
1701-xx | Hard drive format test failure |
1702-xx | Hard drive read test failure |
1703-xx | hard drive write/read/compare test failure |
1704-xx | Hard drive random seek test failure |
1705-xx | Hard drive controller test failure |
1708-xx | Hard drive format bad track test failure |
1710-xx | Hard drive park head test failure |
1715-xx | Hard drive head select test failure |
1716-xx | Hard drive conditional format test failure |
1717-xx | Hard drive ECC test failure |
1719-xx | Hard drive power mode test failure |
1724-xx | Hard drive network preparation test failure |
1736-xx | Hard drive monitoring test failure |
Tape Drive Test Error kódy
Kód | Popis |
1900-xx | Tape drive ID test failure |
1901-xx | Tape drive servo test failure |
1902-xx | Tape drive format or format verification test failure |
1903-xx | Tape sensor test failure |
1904-xx | Tape drive BOT/EOT test failure |
1905-xx | Tape drive read test failure |
1906-xx | Tape drive write/read/compare failure |
1910-xx | Tape erase test failure |
Video Test Error kódy
Kód | Popis |
2401-xx | Graphics controller test failure |
2402-xx | Video memory test failure |
2403-xx | Video attribute test failure |
2404-xx | Video character set test failure |
2405-xx | Video 80 x 25 mode 9 x 14 character cell test failure |
2506-xx | Video 80 x 25 mode 8 x 8 character cell test failure |
2408-xx | Video 320 x 200 mode color set 0 test failure |
2409-xx | Video 320 x 200 mode color set 1 test failure |
2410-xx | Video 640 x 200 mode test failure |
2411-xx | Video screen memory page test failure |
2412-xx | Video gray scale test failure |
2418-xx | ECG/VGC memory test failure |
2419-xx | ECG/VGC ROM checksum test failure |
2420-xx | Graphics attribute test failure |
2421-xx | ECG/VGC 640 x 200 graphics mode test failure |
2422-xx | ECG/VGC 640 x 350 16 color set test failure |
2423-xx | ECG/VGC 640 x 350 64 color set test failure |
2424-xx | ECG/VGC monochrome text mode test failure |
2425-xx | ECG/VGC monochrome graphics mode test failure |
2431-xx | 640 x 480 graphics test failure |
2432-xx | 320 x 200 graphics (245 color mode) test failure |
2448-xx | Advanced VGA controller test failure |
2451-xx | 132 column advanced VGA test failure |
2456-xx | Advanced VGA 256 color test failure |
2458-xx | Advanced VGA BitBLT test failure |
2468-xx | Advanced VGA DAC test failure |
2477-xx | Advanced VGA data path test failure |
2478-xx | Advanced VGA BitBLT test failure |
2480-xx | Advanced VGA linedraw test failure |
Audio Test Error kódy
Kód | Popis |
3206-xx | Audio system internal error |
Network Interface Test Error kódy
Kód | Popis |
6000-xx | Network ID test failure |
6014-xx | Network configuration test failure - Ethernet |
6016-xx | Network reset test failure - Ethernet |
6028-xx | Network internal test failure - Ethernet |
6029-xx | Network external test failure - Ethernet |
6054-xx | Network configuration test failure - Token ring |
6056-xx | Network reset test failure - Token ring |
6068-xx | Network internal test failure - Token ring |
6069-xx | Network external test failure - Token ring |
6089-xx | Network open test failure - Token ring |
SCSI CD-ROM Test Error kódy
Kód | Popis |
6600-xx | ID test failure |
6605-xx | Read test failure |
6608-xx | Controller test failure |
6623-xx | Random read test failure |
SCSI Test Error kódy
Kód | Popis |
65xx-xx | Hard drive related error |
66xx-xx | CD-ROM Drive or PD-CD drive related error |
67xx-xx | Tape drive related error |
xx00-xx | ID based error code |
xx05-xx | Read based error code |
xx06-xx | SA/Media based error code |
xx08-xx | Controller based error code |
xx09-xx | Media erase based error code |
xx23-xx | Random read based error code |
xx-28-xx | Media load/unload based error code |
xxxx-02 | Drive not installed |
xxxx-03 | Media not in drive |
xxxx-05 | Seek failure |
xxxx-06 | Drive timed out |
xxxx-07 | Drive busy |
xxxx-08 | Drive already reserved |
xxxx-09 | Unknown |
xxxx-10 | Unknown |
xxxx-11 | Media soft error |
xxxx-12 | Drive not ready |
xxxx-13 | Media error |
xxxx-14 | Drive hardware error |
xxxx-15 | Illegal drive command |
xxxx-16 | Media has changed |
xxxx-17 | Tape write protect |
xxxx-18 | No data detected |
xxxx-21 | Drive command aborted |
xxxx-24 | Media hard error |
65xx-24 | Media hard error |
66xx-24 | Media hard error |
67xx-24 | Media hard error |
xxxx-25 | Unknown |
xxxx-30 | Controller timed out |
xxxx-31 | Unrecoverable error |
xxxx-32 | Controller/drive disconnected |
xxxx-33 | Illegal controller command |
xxxx-34 | Invalid SCSI bus phase |
xxxx-35 | Invalid SCSI bus phase |
xxxx-36 | Invalid SCSI bus phase |
xxxx-39 | Error status from drive |
xxxx-40 | Target timed out |
xxxx-41 | SCSI bus stayed busy |
xxxx-42 | ACK/REQ lines bad |
xxxx-43 | ACK did not deassert |
xxxx-44 | Parity error |
xxxx-50 | Data pins bad |
xxxx-51 | Data line 7 bad |
xxxx-52 | MSG, C/D, and/or I/O lines bad |
xxxx-53 | BSY never went busy |
xxxx-54 | BSY stayed busy |
xxxx-60 | Controller CONFIG-1 register bad |
xxxx-61 | Controller CONFIG-2 register bad |
xxxx-65 | Media not loaded |
xxxx-90 | Fan failure |
xxxx-91 | Over temperature |
xxxx-99 | Autoloader reported tapes not loaded properly |
Pointing Device Test Error kódy
Kód | Popis |
8601-xx | Mouse test failed |
8602-xx | Interface test failed |
Kód | Popis |
101 | System board interrupt failure (unexpected interrupt) |
102 | BIOS ROM checksum error (PC, XT); timer error (AT, MCA) |
103 | BASIC ROM checksum error (PC, XT); timer interrupt error (AT, MCA) |
104 | Interrupt controller error (PC, XT); protected mode error (AT, MCA) |
105 | Timer failure (PC, XT); 8042 keyboard controller failure (MCA) |
106 | System board converting logic test failure |
107 | System board non-maskable interrupt (NMI) test failure; Hot NMI test failure (MCA) |
108 | System board timer bus test failure |
109 | DMA test memory select failure |
110 | PS/2 system board parity check error (MCA); PS/2 system board memory error (ISA) |
111 | PS/2 adapter memory problem (ISA); PS/2 I/O channel parity check error (MCA) |
112 | PS/2 watchdog timeout error (NMI) |
113 | PS/2 DMA arbitration time out error (NMI) |
114 | PS/2 external ROM checksum error |
115 | BIOS ROM checksum error, cache parity error, or DMA error |
116 | System board read/write error |
118 | System Board parity or L2 cache error |
119 | 2.88MB floppy installed but not supported by the floppy controller |
120 | CPU self test error |
121 | Unexpected hardware interrupt occurred; 256KB ROM checksum error (second 128KB bank) |
129 | System Board Failure |
131 | Cassette wrap test; DMA compatibility registers error |
132 | DMA extended registers error |
133 | DMA verify logic error |
134 | DMA arbitration error |
151 | Battery, real time clock, or CMOS RAM failure |
152 | Real time clock, or CMOS RAM failure |
160 | PS/2 system board ID not recognized |
161 | CMOS configuration lost (battery has died) |
162 | CMOS checksum error, CRC error, or adapter ID mismatch |
163 | CMOS error; Clock is not updating |
164 | CMOS error; CMOS setting does not match memory on system board |
165 | PS/2 adapter ID mismatch |
166 | PS/2 adapter time out; card busy |
167 | PS/2 system clock not updating |
168 | Math coprocessor error in the CMOS configuration |
169 | System board and processor card configuration mismatch |
170 | ASCII setup conflict error |
171 | Rolling bit test failure on CMOS shutdown byte |
172 | Rolling bit test failure on NVRAM diagnostic byte |
173 | Bad CMOS/NVRAM checksum |
174 | Bad system configuration |
175 | Bad EEPROM CRC |
177 | Bad password CRC |
178 | Bad EEPROM |
179 | NVRAM error log full |
180x | Sub address date error in slot x |
181 | Unsupported configuration |
182 | Password switch is not in the writing position |
183 | System halted; password is required |
184 | Bad power on password |
185 | Bad startup sequence |
186 | Password protection hardware error |
187 | Serial number error |
188 | Bad EEPROM checksum |
189 | Too many incorrect password attempts |
191 | Cache controller test failed |
194 | System board memory error |
195 | Configuration read from hibernation area of HDD doesn't match actual configuration |
196 | Read error occurred in hibernation area of HDD |
199 | User indicated device list not correct |
Memory
Kód | Popis |
20x | Memory error |
201 | Memory test failure; error location might be displayed |
202 | Memory address error; lines 00-15 |
203 | Memory address error; lines 16-23 (ISA) or 16-31 (MCA) |
204 | Memory remapped due to error (run diagnostics again) |
205 | Base 128KB memory error; memory remapped |
207 | ROM failure |
210 | System board memory parity error |
211 | Error in first 64KB of RAM |
212 | Watchdog timer error |
213 | DMA bus arbitration time out |
215 | Memory address error; 64KB on daughter/SIP 2 failed |
216 | Memory address error; 64KB on daughter/SIP 1 failed |
221 | ROM to RAM copy failed |
225 | Wrong speed memory on system board |
229 | Memory Error |
230 | Overlapping adapter and planar memory |
231 | Non continuous adapter memory installed |
235 | Stuck data line on memory module |
241 | Memory module 2 failed |
251 | Memory module 3 failed |
Keyboard
Kód | Popis |
301 | Keyboard did not respond correctly |
302 | Keyboard locked |
303 | Keyboard and/or system board interface error; keyboard controller fault |
304 | Keyboard or system unit error |
305 | Keyboard fuse failed on system board |
306 | Unsupported keyboard attached |
341 | Keyboard error |
342 | Keyboard cable error |
343 | Enhancement card or cable error |
365 | Keyboard failure |
366 | Interface cable failure |
367 | Enhancement card or cable failure |
Monochrome Display Adapter
Kód | Popis |
401 | Memory, horizontal sync frequency or vertical sync failure |
408 | User indicated display attribute failure |
416 | User indicated character set failure |
424 | User indicated 80 x 25 mode failure |
432 | MDA card parallel port test failure |
Color Graphics Adapter
Kód | Popis |
501 | CRT error; CGA memory, horizontal sync frequency or video test failure |
503 | CGA adapter controller failed |
508 | User display attribute failure |
516 | User indicated character set failure |
524 | User indicated 80 x 25 mode failure |
532 | User indicated 40 x 25 mode failure |
540 | User indicated 320 x 200 graphics mode failure |
548 | User indicated 640 x 200 graphics mode failure |
556 | User indicated light pen test failed |
564 | User indicated paging test failure |
Floppy Drive/Controller
Kód | Popis |
601 | General diskette or adapter failure |
602 | Diskette boot sector is not valid |
603 | Diskette size error |
604 | Media sense error |
605 | Diskette drive locked |
606 | Diskette verify test failed |
607 | Write protect error |
608 | Drive command error |
610 | Diskette initialization failure |
611 | Drive time out error |
612 | NEC drive controller IC error |
613 | Floppy system DMA error |
614 | Floppy system DMA boundary overrun error |
615 | Drive index timing error |
616 | Drive speed error |
621 | Drive seek error |
622 | Drive cyclic redundancy check (CRC) error |
625 | Controller chip (NEC) seek error |
626 | Diskette data compare error |
627 | Diskette data compare error |
628 | Diskette removed |
630 | Index stuck high; drive A: |
631 | Index stuck low; drive A: |
632 | Track 0 stuck off; drive A: |
632 | Track 0 stuck on; drive A: |
640 | Index stuck high; drive B: |
641 | Index stuck low; drive B: |
642 | Track 0 stuck off; drive B: |
643 | Track 0 stuck on; drive B: |
645 | No index pulse |
646 | Drive track 0 detection failed |
647 | No transitions on read data line |
648 | Format test failed |
649 | Incorrect media type in drive |
650 | Drive speed error |
651 | Format failure |
652 | Verify failure |
653 | Read failure |
654 | Write failure |
655 | Controller error |
656 | Drive failure |
657 | Write protect stuck protected |
658 | Changeline stuck unprotected |
659 | Write protected stuck unprotected |
660 | Changeline stuck unchanged |
Math Coprocessor
Kód | Popis |
701 | Math coprocessor presence/initialization error |
702 | Exception errors test failure |
703 | Rounding test failure |
704 | Arithmetic test 1 failure |
705 | Arithmetic test 2 failure |
706 | Arithmetic test 3 failure; Test is performed on 80387 only |
707 | Combination test failure |
708 | Integer load/store test failure |
709 | Equivalent expressions errors |
710 | Interrupt errors |
711 | Save state errors |
712 | Protected mode test failure |
713 | Voltage test failure |
Parallel Printer Adapter
Kód | Popis |
901 | Data register latch error |
902 | Control register latch error |
903 | Register address decode error |
904 | Address decode error |
910 | Status line wrap connector error |
911 | Status line bit 8 wrap error |
912 | Status line bit 7 wrap error |
913 | Status line bit 6 wrap error |
914 | Status line bit 5 wrap error |
915 | Status line bit 4 wrap error |
916 | Printer adapter interrupt wrap error |
917 | Unexpected printer adapter interrupt |
92x | Feature register error |
Alternate Printer Adapter
Kód | Popis |
1001 | Printer adapter data register latch error |
1002 | Printer adapter control register latch error |
1003 | Printer adapter register address decode error |
1004 | Printer adapter address decode error |
1010 | Status line wrap connector error |
1011 | Status line bit 8 wrap error |
1012 | Status line bit 7 wrap error |
1013 | Status line bit 6 wrap error |
1014 | Status line bit 5 wrap error |
1015 | Status line bit 4 wrap error |
1016 | Printer adapter interrupt wrap error |
1017 | Unexpected printer adapter interrupt |
102x | Feature register error |
Primary Async Communications
Kód | Popis |
1101 | 16450/16550 chip error; serial port A error |
1102 | Card selected feedback error; PC convertible internal modem test failed |
1103 | Port 102h register test failure; PC convertible internal modem dial tone test 1 failed |
1104 | PC convertible internal modem dial tine test 2 failed |
1106 | Serial option cannot be put to sleep |
1107 | Cable error |
1108 | Interrupt request (IRQ) 3 error |
1109 | Interrupt request (IRQ) 4 error |
1110 | 16450/16550 chip register failure |
1111 | Internal wrap test of 16450/16550 chip modem control line failure |
1112 | External wrap test of 16450/16550 chip modem control line failure |
1113 | 16450/16550 chip transmit error |
1114 | 16450/16550 chip receive error |
1115 | 16450/16550 chip receive error; data not equal to transmit data |
1116 | 16450/16550 chip interrupt function error |
1117 | 16450/16550 chip baud rate test failure |
1118 | 16450/16550 chip receive external data wrap test failure |
1119 | 16550 chip first-in/first-out (FIFO) buffer failure |
1120 | Interrupt enable register error; all bits cannot be set |
1121 | Interrupt enable register error; all bits cannot be reset |
1122 | Interrupt pending; stuck on |
1123 | Interrupt ID register; stuck on |
1124 | Modem cannot register error; all bits cannot be set |
1125 | Modem cannot register error; all bits cannot be reset |
1126 | Modem status register error; all bits cannot be set |
1127 | Modem status register error; all bits cannot be reset |
1128 | Interrupt ID error |
1129 | Cannot force overrun error |
1130 | No modem status interrupt |
1131 | Invalid interrupt pending |
1132 | No data ready |
1133 | No data available interrupt |
1134 | No transmit holding interrupt |
1135 | No interrupts |
1136 | No received line status interrupt |
1137 | No receive data available |
1138 | Transmit holding register not empty |
1139 | No modem status interrupt |
1140 | Transmit holding register not empty |
1141 | No interrupts |
1142 | No interrupt 4 |
1143 | No interrupt 3 |
1144 | No data transferred |
1145 | Maximum baud rate error |
1146 | Minimum baud rate error |
1148 | Time out error |
1149 | Invalid data returned |
1150 | Modem status register error |
1151 | No data set ready and delta data set ready |
1152 | No data set ready |
1153 | No delta data set ready |
1154 | Modem status register not clear |
1155 | No clear to send and delta clear to send |
1156 | No clear to send |
1157 | No delta clear to send |
Alternate Async Communications
Kód | Popis |
1201 | 16450/16550 chip error |
1202 | Card selected feedback error |
1203 | Port 02h register test failure |
1206 | Serial option cannot be put to sleep |
1207 | Cable error |
1208 | Interrupt request (IRQ) 3 error |
1209 | Interrupt request (IRQ) 4 error |
1210 | 16450/16550 chip register failure |
1211 | Internal wrap test of 16450/16550 chip modem control line failure |
1212 | External wrap test of 16450/16550 chip modem control line failure |
1213 | 16450/16550 chip transmit error |
1214 | 16450/16550 chip receive error |
1215 | 16450/16550 chip receive error; data not equal to transmit data |
1216 | 16450/16550 chip interrupt function error |
1217 | 16450/16550 chip baud rate test failure |
1218 | 16450/16550 chip receive external data wrap test failure |
1219 | 16550 chip first-in/first-out (FIFO) buffer failure |
1220 | Interrupt enable register error; all bits cannot be set |
1221 | Interrupt enable register error; all bits cannot be reset |
1222 | Interrupt pending; stuck on |
1223 | Interrupt ID register; stuck on |
1224 | Modem cannot register error; all bits cannot be set |
1225 | Modem cannot register error; all bits cannot be reset |
1226 | Modem status register error; all bits cannot be set |
1227 | Modem status register error; all bits cannot be reset |
1228 | Interrupt ID error |
1229 | Cannot force overrun error |
1230 | No modem status interrupt |
1231 | Invalid interrupt pending |
1232 | No data ready |
1233 | No data available interrupt |
1234 | No transmit holding interrupt |
1235 | No interrupts |
1236 | No received line status interrupt |
1237 | No receive data available |
1238 | Transmit holding register not empty |
1239 | No modem status interrupt |
1240 | Transmit holding register not empty |
1241 | No interrupts |
1242 | No interrupt 4 |
1243 | No interrupt 3 |
1244 | No data transferred |
1245 | Maximum baud rate error |
1246 | Minimum baud rate error |
1248 | Time out error |
1249 | Invalid data returned |
1250 | Modem status register error |
1251 | No data set ready and delta data set ready |
1252 | No data set ready |
1253 | No delta data set ready |
1254 | Modem status register not clear |
1255 | No clear to send and delta clear to send |
1256 | No clear to send |
1257 | No delta clear to send |
Game Control Adapter
Kód | Popis |
1301 | Game control adapter test failure |
1302 | Joystick test failure |
Matrix Printer
Kód | Popis |
1401 | Printer test failure |
1402 | Printer not ready, not on line, or out of paper |
1403 | Printer no paper error |
1404 | Matrix printer test failure; system board time out |
1405 | Parallel adapter failure |
1406 | Printer presence test failed |
Synchronous Data Link Control Communications (SDLC) Adapter
Kód | Popis |
1501 | SDLC adapter test failure |
1510 | 8255 port B failure |
1511 | 8255 port A failure |
1512 | 8255 port C failure |
1513 | 8253 timer #1 did not reach terminal count |
1514 | 8253 timer #1 stuck on |
1515 | 8253 timer #0 did not reach terminal count |
1516 | 8253 timer #0 stuck on |
1517 | 8253 timer #2 did not reach terminal count |
1518 | 8253 timer #2 stuck on |
1519 | 8273 port B error |
1520 | 8273 port A error |
1521 | 8273 command/read time out |
1522 | Interrupt level 4 failure |
1523 | Ring indicate stuck on |
1524 | Receive clock stuck on |
1525 | Transmit clock stuck on |
1526 | Test indicate stuck on |
1527 | Ring indicate stuck on |
1528 | Receive clock stuck on |
1529 | Transmit clock stuck on |
1530 | Test indicate not on |
1531 | Data set ready not on |
1532 | Carrier detect not on |
1533 | Clear to send not on |
1534 | Data set ready stuck on |
1535 | Carrier detect stuck on |
1536 | Clear to send stuck on |
1537 | Interrupt level 3 failure |
1538 | Receive interrupt results error |
1539 | Wrap data compare error |
1540 | Direct memory access channel 1 error |
1541 | Direct memory access channel 1 error |
1542 | 8273 error checking or status reporting error |
1547 | Stray interrupt level 4 |
1548 | Stray interrupt level 3 |
1549 | Interrupt presentation sequence time out |
Display Station Emulation Adapter (DSEA)
Kód | Popis |
1604 | DSEA or twinaxial network error |
1608 | DSEA or twinaxial network error |
1624 | DSEA error |
1634 | DSEA error |
1644 | DSEA error |
1652 | DSEA error |
1654 | DSEA error |
1658 | DSEA error |
1662 | DSEA interrupt level error |
1664 | DSEA error |
1668 | DSEA interrupt level error |
1669 | DSEA diagnostics error; use 3.0 or higher |
1674 | DSEA diagnostics error; use 3.0 or higher; DSEA station address error |
1684 | DSEA device address error |
1688 | DSEA device address error |
Hard Drive and Controller
Kód | Popis |
1701 | Fixed disk or adapter general error |
1702 | Drive and controller time out error |
1703 | Drive seek error |
1704 | Drive controller failed |
1705 | Drive sector not found error |
1706 | Write fault error |
1707 | Drive track 00 error |
1708 | Head select error |
1709 | Bad ECC returned |
1710 | Sector buffer overrun |
1711 | Bad address mark |
1712 | Internal controller diagnostics failure |
1713 | Data compare error |
1714 | Drive not ready |
1715 | Track 00 indicator error |
1716 | Diagnostics cylinder errors |
1717 | Surface read errors |
1718 | Hard drive error |
1720 | Bad diagnostics cylinder |
1726 | Data compare error |
1730 | Drive controller error |
1731 | Drive controller error |
1732 | Drive controller error |
1733 | BIOS undefined error return |
1735 | Bad command error |
1736 | Data corrected error |
1737 | Bad drive track error |
1738 | Bad sector error |
1739 | Bad initialization error |
1740 | Bad sense error |
1750 | Drive verify error |
1751 | Drive read error |
1752 | Drive write error |
1753 | Drive random read test failure |
1754 | Drive seek test failure |
1755 | Drive controller failure |
1756 | Controller ECC test failure |
1757 | Controller head select failure |
1780 | Drive seek failure (drive 0) |
1781 | Drive seek failure (drive 1) |
1782 | Hard disk controller failure |
1790 | Diagnostic cylinder read error (drive 0) |
1791 | Diagnostic cylinder read error (drive 1) |
I/O Expansion Unit
Kód | Popis |
1801 | Expansion unit POST error |
1810 | Enable/Disable failure |
1811 | Extender card wrap test failure while disabled |
1812 | High order address lines failure while disabled |
1813 | Wait state failure while disabled |
1814 | Enable/disable could not be set on |
1815 | Wait state failure while enabled |
1816 | Extender card wrap test failure while enabled |
1817 | High order address lines failure while enabled |
1818 | Disable not functioning |
1819 | Wait request switch not set correctly |
1820 | Receiver card wrap test failed |
1821 | Receiver high order address lines failure |
Binary Synchronous Communications (BSC) Adapter
Kód | Popis |
2001 | BSC adapter test failure |
2010 | 8255 port A failure |
2011 | 8255 port B failure |
2012 | 8255 port C failure |
2013 | 8253 timer #1 did not reach terminal count |
2014 | 8253 timer #1 stuck on |
2015 | 8253 timer #2 did not reach terminal count |
2016 | 8253 timer #2 stuck on |
2017 | 8251 data set ready failed to come on |
2018 | 8251 clear to send not sensed |
2019 | 8251 data set ready stuck on |
2020 | 8151 clear to send stuck on |
2021 | 8151 hardware reset failure |
2022 | 8251 software reset failure |
2023 | 8251 software "error reset" failure |
2024 | 8251 transmit ready did not come on |
2025 | 8251 receive ready did not come on |
2026 | 8251 could not force "overrun" error status |
2027 | Interrupt failure; no timer interrupt |
2028 | Interrupt failure; transmit; replace card or planar |
2029 | Interrupt failure; transmit; replace card |
2030 | Interrupt failure; receive; replace card or planar |
2031 | Interrupt failure; receive; replace card |
2033 | Ring indicate stuck on |
2034 | Receive clock stuck on |
2035 | transmit clock stuck on |
2036 | Test indicate stuck on |
2037 | Ring indicate stuck on |
2038 | Receive clock not on |
2039 | Transmit clock not on |
2040 | Test indicate not on |
2041 | Data set ready not on |
2042 | Carrier detect not on |
2043 | Clear to send not on |
2044 | Data set ready stuck on |
2045 | Carrier detect stuck on |
2046 | Clear to send stuck on |
2047 | Unexpected transmit interrupt |
2048 | Unexpected receive interrupt |
2050 | 8251 detected overrun error |
2051 | Lost data set ready during data wrap |
2052 | Receive time out during data wrap |
Alternate Binary Synchronous Communications (BSC) Adapter
Kód | Popis |
2101 | BSC adapter test failure |
2110 | 8255 port A failure |
2111 | 8255 port B failure |
2112 | 8255 port C failure |
2113 | 8253 timer #1 did not reach terminal count |
2114 | 8253 timer #1 stuck on |
2115 | 8253 timer #2 did not reach terminal count |
2116 | 8253 timer #2 stuck on |
2117 | 8251 data set ready failed to come on |
2118 | 8251 clear to send not sensed |
2119 | 8251 data set ready stuck on |
2120 | 8151 clear to send stuck on |
2121 | 8151 hardware reset failure |
2122 | 8251 software reset failure |
2123 | 8251 software "error reset" failure |
2124 | 8251 transmit ready did not come on |
2125 | 8251 receive ready did not come on |
2126 | 8251 could not force "overrun" error status |
2127 | Interrupt failure; no timer interrupt |
2128 | Interrupt failure; transmit; replace card or planar |
2129 | Interrupt failure; transmit; replace card |
2130 | Interrupt failure; receive; replace card or planar |
2131 | Interrupt failure; receive; replace card |
2133 | Ring indicate stuck on |
2134 | Receive clock stuck on |
2135 | transmit clock stuck on |
2136 | Test indicate stuck on |
2137 | Ring indicate stuck on |
2138 | Receive clock not on |
2139 | Transmit clock not on |
2140 | Test indicate not on |
2141 | Data set ready not on |
2142 | Carrier detect not on |
2143 | Clear to send not on |
2144 | Data set ready stuck on |
2145 | Carrier detect stuck on |
2146 | Clear to send stuck on |
2147 | Unexpected transmit interrupt |
2148 | Unexpected receive interrupt |
2150 | 8251 detected overrun error |
2151 | Lost data set ready during data wrap |
2152 | Receive time out during data wrap |
Cluster Adapter
Kód | Popis |
22xx | A cluster adapter error has occurred - replace the cluster adapter |
Plasma Monitor Adapter
Kód | Popis |
23xx | A plasma adapter display error has occurred - replace the plasma display monitor assembly |
Enhanced Graphics Adapter or Video Graphics Adapter
Kód | Popis |
2401 | Video adapter test failure |
2402 | Video display error |
2408 | User indicated display attribute test failed |
2409 | Video display error |
2410 | Video adapter error; video port error |
2416 | User indicated character set test failed |
2424 | User indicated 80 x 25 mode failure |
2432 | User indicated 40 x 25 mode failure |
2440 | User indicated mode 320 x 200 mode failure |
2448 | User indicated 640 x 200 mode failure |
2456 | User indicated light pen test failure |
2464 | User indicated paging test failure |
Alternate Enhanced Graphics Adapter
Kód | Popis |
2501 | Video adapter test failure |
2502 | Video display error |
2508 | User indicated display attribute test failed |
2509 | Video display error |
2510 | Video adapter error; video port error |
2516 | User indicated character set test failed |
2524 | User indicated 80 x 25 mode failure |
2532 | User indicated 40 x 25 mode failure |
2540 | User indicated mode 320 x 200 mode failure |
2548 | User indicated 640 x 200 mode failure |
2556 | User indicated light pen test failure |
2564 | User indicated paging test failure |
XT or AT/370 370-M (Memory) and 370-P (Processor) Adapter
Kód | Popis |
2601 | 370-M adapter error |
2655 | 370-M adapter error |
2657 | 370-M adapter error |
2668 | 370-M adapter error |
2672 | 370-M adapter error |
2673 | 370-P adapter error |
2674 | 370-P adapter error |
2677 | 370-P adapter error |
2680 | 370-P adapter error |
2681 | 370-M adapter error |
2682 | 370-P adapter error |
2694 | 370-P adapter error |
2697 | 370-P adapter error |
2698 | XT or AT/370 diagnostic diskette error |
XT or AT/370 3277-EM (Emulation) Adapter Error:
Kód | Popis |
2701 | 3277-EM adapter error |
2702 | 3277-EM adapter error |
2703 | 3277-EM adapter error |
3728/3729 Emulation Adapter or 3270 Connection Adapter
Kód | Popis |
28xx | An emulation adapter fault has occurred - replace the adapter |
Color/Graphics Printer
Kód | Popis |
29xx | A general fault has been detected with the printer or it's printer port - replace the adapter |
Primary PC Network Adapter
Kód | Popis |
3001 | Network adapter test failure |
3002 | ROM checksum test failure |
3003 | Unit ID PROM test failure |
3004 | RAM test failure |
3005 | Host interface controller 9HIC) test failure |
3006 | +/- 12Vdc test failure |
3007 | Digital loopback test failure |
3008 | Host detected HIC failure |
3009 | Sync signal failure and no go bit |
3010 | HIC test OK and no go bit |
3011 | Go bit OK, but no command 41 |
3012 | Card not present |
3013 | Digital failure fall through |
3015 | Analog failure |
3041 | Hot carrier on other card |
3042 | Hot carrier on this card |
Secondary PC Network Adapter
Kód | Popis |
3101 | Network adapter test failure |
3102 | ROM checksum test failure |
3103 | Unit ID PROM test failure |
3104 | RAM test failure |
3105 | Host interface controller 9HIC) test failure |
3106 | +/- 12Vdc test failure |
3107 | Digital loopback test failure |
3108 | Host detected HIC failure |
3109 | Sync signal failure and no go bit |
3110 | HIC test OK and no go bit |
3111 | Go bit OK, but no command 41 |
3112 | Card not present |
3113 | Digital failure fall through |
3115 | Analog failure |
3141 | Hot carrier on other card |
3142 | Hot carrier on this card |
3270 PC/AT Display
Kód | Popis |
32xx | A fault has been detected in the display system - replace the display system |
Compact Printer
Kód | Popis |
33xx | A fault has been detected in the printer or printer adapter - replace the printer or printer adapter |
Enhanced Display Station Emulation Adapter (EDSEA)
Kód | Popis |
3504 | Adapter connected to twinaxial cable during offline test |
3508 | Workstation address error |
3509 | Diagnostic program failure |
3540 | Workstation address invalid |
3588 | Adapter address switch error |
3599 | Diagnostic program failure |
General Purpose Interface Bus (GPIB) Adapter
Kód | Popis |
3601 | Adapter test failure |
3602 | Serial poll mode register write error |
3603 | Adapter address error |
3610 | Adapter listen error |
3611 | Adapter talk error |
3612 | Adapter control error |
3613 | Adapter standby error |
3614 | Adapter asynchronous control error |
3615 | Adapter asynchronous control error |
3616 | Adapter error; cannot pass control |
3617 | Adapter error; cannot address to listen |
3618 | Adapter error; cannot unaddress to listen |
3619 | Adapter error; cannot address to talk |
3620 | Adapter error; cannot unaddress to talk |
3621 | Adapter error; cannot address to listen with extended addressing |
3622 | Adapter error; cannot unaddress to listen with extended addressing |
3623 | Adapter error; cannot address to talk with extended addressing |
3624 | Adapter error; cannot unaddress to talk with extended addressing |
3625 | Write to self error |
3626 | Generate handshake error |
3627 | Cannot detect Device Clear message error |
3628 | Cannot detect Selected Device Clear message error |
3629 | Cannot detect end with end of identify |
3630 | Cannot detect end of transmission with end of identify |
3631 | Cannot detect end with 0 bot end of string |
3632 | Cannot detect end with 7 bit end of string |
3633 | Cannot detect group execute trigger |
3634 | Mode 3 addressing error |
3635 | Cannot recognize undefined command |
3636 | Cannot detect remote, remote changed, lockout, or lockout changed |
3639 | Cannot conduct serial poll |
3640 | Cannot conduct parallel poll |
3650 | Adapter error; direct memory access (DMA) to 7210 |
3651 | Data error; error on direct memory access (DMA) to 7210 |
3652 | Adapter error; direct memory access (DMA) from 7210 |
3653 | Data error on direct memory access (DMA) from 7210 |
3658 | Uninvoked interrupt received |
3659 | Cannot interrupt on address status changed |
3660 | Cannot interrupt on address status changed |
3661 | Cannot interrupt on command output |
3662 | Cannot interrupt on data out |
3663 | Cannot interrupt on data in |
3664 | Cannot interrupt on error |
3665 | Cannot interrupt on device clear |
3666 | Cannot interrupt on end |
3667 | Cannot interrupt on device execute trigger |
3668 | Cannot interrupt on address pass through |
3669 | Cannot interrupt on command pass through |
3670 | Cannot interrupt on remote changed |
3671 | Cannot interrupt on lockout changed |
3672 | Cannot interrupt on service request in |
3673 | Cannot interrupt on terminal count on direct memory access to 7210 |
3674 | Cannot interrupt on terminal count on direct memory access from 7210 |
3675 | Spurious direct memory access terminal count interrupt |
3697 | Illegal direct memory access configuration setting detected |
3698 | Illegal interrupt level setting detected |
System Board SCSI Controller
Kód | Popis |
37xx | the system board SCSI controller has failed - replace the motherboard |
Data Acquisition Adapter
Kód | Popis |
3801 | Adapter test failure |
3810 | Timer read test failure |
3811 | Timer interrupt test failure |
3812 | Binary input 13 test failure |
3813 | Binary input 13 test failure |
3814 | Binary output 14 interrupt request test failure |
3815 | Binary output 0 count in test failure |
3816 | Binary input strobe (STB) count out test failure |
3817 | Binary output 0 clear to send (CTS) test failure |
3818 | Binary output 1, binary input 0 test failure |
3819 | Binary output 2, binary input 1 test failure |
3820 | Binary output 3, binary input 2 test failure |
3821 | Binary output 4, binary input 3 test failure |
3822 | Binary output 5, binary input 4 test failure |
3823 | Binary output 6, binary input 5 test failure |
3824 | Binary output 7, binary input 6 test failure |
3825 | Binary output 8, binary input 7 test failure |
3826 | Binary output 9, binary input 8 test failure |
3827 | Binary output 10, binary input 9 test failure |
3828 | Binary output 11, binary input 10 test failure |
3829 | Binary output 12, binary input 11 test failure |
3830 | Binary output 13, binary input 12 test failure |
3831 | Binary output 15, analog input CE test failure |
3832 | Binary output strobe, binary output GATE test failure |
3833 | Binary input clear to send, binary output HOLD test failure |
3834 | Analog input command output (CO), binary input 15 test failure |
3835 | Counter interrupt test failure |
3836 | Counter read test failure |
3837 | Analog output 0 ranges test failure |
3838 | Analog output 1 ranges test failure |
3839 | Analog input 0 values test failure |
3840 | Analog input 1 values test failure |
3841 | Analog input 2 values test failure |
3842 | Analog input 3 values test failure |
3843 | Analog input interrupt test failure |
3844 | Analog input 23 address or value test failure |
Professional Graphics Adapter (PGA)
Kód | Popis |
3901 | PGA test failed |
3902 | ROM 1 self test failed |
3903 | ROM 2 self test failed |
3904 | RAM self test failed |
3905 | Cold start cycle power error |
3906 | Data error in communications RAM |
3907 | Address error in communications RAM |
3908 | Bad data reading/writing 6845 like register |
3909 | Bad data in lower E0h bytes reading/writing 6845 like registers |
3910 | Graphics controller display bank output latches error |
3911 | Basic clock error |
3912 | Command control error |
3913 | Vertical sync scanner error |
3914 | Horizontal sync scanner error |
3915 | Intech error |
3916 | Look up table address error |
3917 | Look up table red RAM chip error |
3918 | Look up table green RAM chip error |
3919 | Look up table blue RAM chip error |
3920 | Look up table data latch error |
3921 | Horizontal display error |
3922 | Vertical display error |
3923 | Light pen error |
3924 | Unexpected error |
3925 | Emulator addressing error |
3926 | Emulator data latch error |
3927 | Base for error codes 3928-3930 |
3928 | Emulator RAM error |
3929 | Emulator RAM error |
3930 | Emulator RAM error |
3931 | Emulator horizontal/vertical display problem |
3932 | Emulator cursor position error |
3933 | Emulator attribute display problem |
3934 | Emulator cursor display error |
3935 | Fundamental emulation RAM problem |
3936 | Emulation character set problem |
3937 | Emulation graphics display error |
3938 | Emulation character display problem |
3939 | Emulation bank select error |
3940 | Adapter RAM U2 error |
3941 | Adapter RAM U4 error |
3942 | Adapter RAM U6 error |
3943 | Adapter RAM U8 error |
3944 | Adapter RAM U10 error |
3945 | Adapter RAM U1 error |
3946 | Adapter RAM U3 error |
3947 | Adapter RAM U5 error |
3948 | Adapter RAM U7 error |
3949 | Adapter RAM U9 error |
3950 | Adapter RAM U12 error |
3951 | Adapter RAM U14 error |
3952 | Adapter RAM U16 error |
3953 | Adapter RAM U18 error |
3954 | Adapter RAM U20 error |
3955 | Adapter RAM U11 error |
3956 | Adapter RAM U13 error |
3957 | Adapter RAM U15 error |
3958 | Adapter RAM U17 error |
3959 | Adapter RAM U19 error |
3960 | Adapter RAM U22 error |
3961 | Adapter RAM U24 error |
3962 | Adapter RAM U26 error |
3963 | Adapter RAM U28 error |
3964 | Adapter RAM U30 error |
3965 | Adapter RAM U21 error |
3966 | Adapter RAM U23 error |
3967 | Adapter RAM U25 error |
3968 | Adapter RAM U27 error |
3969 | Adapter RAM U29 error |
3970 | Adapter RAM U32 error |
3971 | Adapter RAM U34 error |
3972 | Adapter RAM U36 error |
3973 | Adapter RAM U38 error |
3974 | Adapter RAM U40 error |
3975 | Adapter RAM U31 error |
3976 | Adapter RAM U33 error |
3977 | Adapter RAM U35 error |
3978 | Adapter RAM U37 error |
3979 | Adapter RAM U39 error |
3980 | Graphics controller RAM timing error |
3981 | Graphics controller read/write latch error |
3982 | Shift register bus output latches error |
3983 | Addressing error (vertical column of memory; U2 at top) |
3984 | Addressing error (vertical column of memory; U4 at top) |
3985 | Addressing error (vertical column of memory; U6 at top) |
3986 | Addressing error (vertical column of memory; U6 at top) |
3987 | Addressing error (vertical column of memory; U8 at top) |
3988 | Addressing error (vertical column of memory; U10 at top) |
3989 | Horizontal bank latch errors |
3990 | Horizontal bank latch errors |
3991 | Horizontal bank latch errors |
3992 | RAG/CAG graphics controller error |
3993 | Multiple write modes; nibble mask errors |
3994 | Row nibble (display RAM) error |
3995 | Graphics controller addressing error |
Display Attachment Unit and 5279 Display
Kód | Popis |
44xx | A fault has occurred with the display system - replace the display system |
IEEE 488 (GPIB) Interface Adapter
Kód | Popis |
45xx | A fault has occurred with the GPIB - replace the adapter |
ARTIC Multiport/2 Interface Adapter
Kód | Popis |
4611 | ARTIC adapter error |
4612/4613 | Memory module error |
4630 | ARTIC adapter error |
4640/4641 | Memory module error |
4650 | ARTIC interface cable error |
Internal Modem
Kód | Popis |
48xx | The internal modem has failed - replace the modem |
Alternate Internal Modem
Kód | Popis |
49xx | The alternate internal modem has failed - replace the alternate internal modem |
PC Convertible LCD
Kód | Popis |
5001 | LCD buffer failure |
5002 | LCD font buffer failure |
5003 | LCD controller failure |
5004 | User indicated PEL/drive test failure |
5008 | User indicated display attribute test failed |
5016 | User indicated character set test failed |
5020 | User indicated alternate character set test failure |
5024 | User indicated 80 x 25 mode test failure |
5032 | User indicated 40 x 25 mode test failure |
5040 | User indicated 320 x 200 graphics test failure |
5048 | User indicated 640 x 200 graphics test failure |
5064 | User indicated paging test failure |
PC Convertible Portable Printer
Kód | Popis |
5101 | Portable printer interface failure |
5102 | Portable printer busy error |
5103 | Portable printer paper or ribbon error |
5104 | Portable printer time out |
5105 | User indicated print pattern test error |
Financial Communication System
Kód | Popis |
56xx | A fault has been detected in the financial communication system - replace the financial communication system |
Phoenix BIOS/Chipset Specific
Kód | Popis |
7000 | Chipset CMOS failure |
7001 | Shadow RAM failure (ROM not shadowed to RAM) |
7002 | Chipset CMOS configuration data error |
Voice Communications Adapter (VCA)
Kód | Popis |
7101 | Adapter test failure |
7102 | Instruction or external data memory error |
7103 | PC to VCA interrupt error |
7104 | Internal data memory error |
7105 | DMA error |
7106 | Internal registers error |
7107 | Interactive shared memory error |
7108 | VCA to PC interrupt error |
7109 | DC wrap error |
7111 | External analog wrap and tone output error |
7114 | Telephone attachment test failure |
3 1/2" Floppy Disk Drive
Kód | Popis |
7301 | Diskette drive/adapter test failure |
7306 | Diskette change line error |
7307 | Write protected diskette |
7308 | drive command error |
7310 | Diskette initialization failure track 00 error |
7311 | Drive time out error |
7312 | NEC drive controller IC error |
7313 | DMA error |
7314 | DMA boundary overrun error |
7315 | Drive index timing error |
7316 | Drive speed error |
7321 | Drive seek error |
7322 | Drive CRC check error |
7323 | Sector not found error |
7324 | Address mark error |
7325 | NEC controller IC seek error |
8514/A Display Adapter
Kód | Popis |
7426 | 8514 display error |
7440 | 8514/A memory module 31 error |
7441 | 8514/A memory module 30 error |
7442 | 8514/A memory module 29 error |
7443 | 8514/A memory module 28 error |
7444 | 8514/A memory module 22 error |
7445 | 8514/A memory module 21 error |
7446 | 8514/A memory module 18 error |
7447 | 8514/A memory module 17 error |
7448 | 8514/A memory module 32 error |
7449 | 8514/A memory module 14 error |
7450 | 8514/A memory module 13 error |
7451 | 8514/A memory module 12 error |
7452 | 8514/A memory module 06 error |
7453 | 8514/A memory module 05 error |
7454 | 8514/A memory module 02 error |
7455 | 8514/A memory module 01 error |
7460 | 8514/A memory module 16 error |
7461 | 8514/A memory module 27 error |
7462 | 8514/A memory module 26 error |
7463 | 8514/A memory module 25 error |
7464 | 8514/A memory module 24 error |
7465 | 8514/A memory module 23 error |
7466 | 8514/A memory module 20 error |
7467 | 8514/A memory module 19 error |
7468 | 8514/A memory module 15 error |
7469 | 8514/A memory module 11 error |
7470 | 8514/A memory module 10 error |
7471 | 8514/A memory module 09 error |
7472 | 8514/A memory module 08 error |
7473 | 8514/A memory module 07 error |
7474 | 8514/A memory module 04 error |
7475 | 8514/A memory module 03 error |
4216 Page Printer Adapter
Kód | Popis |
7601 | Adapter test failure |
7602 | Adapter card error |
7603 | Printer error |
7604 | Printer cable error |
PCMCIA Adapter
Kód | Popis |
8081 | Presence test failure (PCMCIA revision number also checksum) |
8082 | PCMCIA register test failure |
PS/2 Speech Adapter
Kód | Popis |
84xx | A fault has occurred with the speech adapter - replace the speech adapter |
2MB XMA Memory Adapter
Kód | Popis |
85xx | A fault has occurred with the memory module - replace the memory module |
PS/2 Pointing Device
Kód | Popis |
8601 | Pointing device: mouse time out error |
8602 | Pointing device: mouse interface error |
8603 | System board: mouse interrupt error |
8604 | Pointing device or system board error |
8611 | System bus error |
8612 | TrackPoint II error |
8613 | System bus or TrackPoint II error |
MIDI Interface
Kód | Popis |
89xx | A fault has occurred with the MIDI adapter - replace the MIDI adapter |
3363 Worm Optical Drive/Adapter
Kód | Popis |
91xx | A fault has occurred in the drive or adapter - replace the adapter or the drive |
SCSI Adapter (W/32 bit Cache):
Kód | Popis |
96xx | A fault has occurred with the SCSI adapter - replace the SCSI adapter |
Multiprotocol Adapter
Kód | Popis |
10001 | Presence test failure |
10002 | Card selected feedback error |
10003 | Port 102h register test failure |
10004 | Port 103h register test failure |
10006 | Serial option cannot be disabled |
10007 | Cable error |
10008 | IRQ 3 error |
10009 | IRQ 4 error |
10010 | UART register failure |
10011 | Internal wrap test of UART control line failed |
10012 | External wrap test of UART control line failed |
10013 | UART transmit error |
10014 | UART receive error |
10015 | UART receive error - data not equal to transmit data |
10016 | UART interrupt error |
10017 | UART baud rate test failure |
10018 | UART receive external wrap test failure |
10019 | UART FIFO buffer failure |
10026 | 8255 port A error |
10027 | 8255 port B error |
10028 | 8255 port C error |
10029 | 8254 timer 0 error |
10030 | 8254 timer 1 error |
10031 | 8254 timer 2 error |
10032 | Bi-sync data set ready (DSR) response error |
10033 | Bi-sync clear to send(CTS) error |
10034 | 8251 hardware reset test failed |
10035 | 8251 function generator |
10036 | 8251 status error |
10037 | Bi-sync timer interrupt error |
10038 | Bi-sync transmit interrupt error |
10039 | Bi-sync receive interrupt error |
10040 | Stray IRQ 3 error |
10041 | Stray IRQ 4 error |
10042 | Bi-sync external wrap error |
10044 | Bi-sync data wrap error |
10045 | Bi-sync line status error |
10046 | Bi-sync time out error during wrap test |
10050 | 8273 command acceptance or time out error |
10051 | 8273 port A error |
10052 | 8273 port B error |
10053 | SDLC modem status logic error |
10054 | SDLC timer IRQ 4 error |
10055 | SDLC IRQ 4 error |
10056 | SDLC external wrap error |
10057 | SDLC interrupt results error |
10058 | SDLC data wrap error |
10059 | SDLC transmit interrupt error |
10060 | SDLC receive interrupt error |
10061 | DMA channel 1 transmit error |
10062 | DMA channel 1 receive error |
10063 | 8273 status detect failure |
10064 | 8273 error detect failure |
Internal 300/1200Bps Modem
Kód | Popis |
10101 | Presence detect failure |
10102 | Card selected feedback error |
10103 | Port 102h register test error |
10106 | Serial option cannot be disabled |
10108 | IRQ 3 error |
10109 | IRQ 4 error |
10110 | UART chip register failure |
10111 | UART control line internal wrap test failure |
10113 | UART transmit error |
10114 | UART receive error |
10115 | UART error - transmit and receive data not equal |
10116 | UART interrupt function error |
10117 | UART baud rate test failure |
10118 | UART interrupt driven receive external data wrap test failure |
10125 | Modem reset result code error |
10126 | Modem general result code error |
10127 | Modem S registers read/write error |
10128 | Modem echo on/off error |
10129 | Modem enable/disable result codes error |
10130 | Modem enable number/word result codes error |
10133 | Connect results for 300 baud not received |
10134 | Connect results for 1200 baud not received |
10135 | Modem fails local analog loopback 300 baud test |
10136 | Modem fails local analog loopback 1200 baud test |
10137 | Modem does not respond to escape/reset sequence |
10138 | S register 13 shows incorrect parity or number of data bits |
10139 | S register 15 shows incorrect bit rate |
ESDI or MCA IDE Fixed Disk or Adapter
Kód | Popis |
10450 | Read/write test failed |
10451 | read verify test failed |
10452 | Seek test failed |
10453 | Wrong drive type indicated |
10454 | Controller sector buffer test failure |
10455 | Controller invalid failure |
10456 | Controller diagnostic command failure |
10461 | Drive format error |
10462 | Controller head select error |
10463 | Drive read/write sector error |
10464 | Drive primary detect map unreadable |
10465 | Controller: error-correction code (ECC) 8 bit error |
10466 | Controller: error correction code (ECC) 9 bit error |
10467 | Drive soft seek error |
10468 | Drive head seek error |
10469 | Drive soft error count exceeded |
10470 | Controller attachment diagnostic error |
10471 | Controller wrap mode interface error |
10472 | Controller wrap mode drive select error |
10473 | Read verify test errors |
10480 | Seek failure: drive 0 |
10481 | Seek failure: drive 1 |
10482 | Controller transfer acknowledge error |
10483 | Controller reset failure |
10484 | Controller: head select 3 error |
10485 | Controller: head select 2 error |
10486 | Controller: head select 1 error |
10487 | Controller: head select 0 error |
10488 | Controller: read gate - command complete 2 error |
10489 | Controller: write gate - command complete 1 error |
10490 | Diagnostic area read error: drive 0 |
10491 | Diagnostic area read error: drive 1 |
10492 | Controller error, drive 1 |
10493 | Reset error, drive 1 |
10499 | Controller failure |
5 1/4 External Disk Drive or Adapter
Kód | Popis |
107xx | A fault has occurred with the external disk drive or adapter - replace the disk drive or adapter |
SCSI Adapter (16 bit without Cache)
Kód | Popis |
112xx | A fault has occurred with the SCSI adapter - replace the SCSI adapter |
System Board SCSI Adapter
Kód | Popis |
113xx | A fault has occurred with the system board SCSI adapter - replace the motherboard |
Processor Complex
Kód | Popis |
129005 | DMA error |
12901 | Processor board: processor test failure |
12902 | Processor board: cache test failure |
12904 | Second level cache failure |
12905 | Cache enable/disable errors |
12907 | Cache fatal error |
12908 | Cache POST program error |
12912x | Hardware failure |
12913x | Micro channel bus time out |
12914x | Software failure |
12915x | Processor complex error |
12916x | Processor complex error |
12917x | Processor complex error |
12918x | Processor complex error |
12919x | Processor complex error |
12940x | Processor complex failure |
12950x | Processor complex failure |
129900 | Processor complex serial number mismatch |
P70/P75 Plasma Display and Adapter
Kód | Popis |
14901 | Plasma display adapter failure |
14902 | Plasma display adapter failure |
14922 | Plasma display failure |
14932 | External display device failure |
XGA Display Adapter
Kód | Popis |
152xx | A fault has occurred with the XGA display adapter - replace the display adapter |
120MB Internal Tape Drive
Kód | Popis |
164xx | A fault has occurred with the internal tape drive - replace the tape drive |
6157 Streaming Tape Drive
Kód | Popis |
16520 | Streaming tape drive failure |
16540 | Tape attachment adapter failure |
Primary Token Ring Network Adapter
Kód | Popis |
166xx | A fault has occurred with the network adapter - replace the network adapter |
Alternate Token Ring Network Adapter
Kód | Popis |
167xx | A fault has occurred with the network adapter - replace the network adapter |
PS/2 Wizard Adapter
Kód | Popis |
18001 | Interrupt controller failure |
18002 | Incorrect timer count |
18003 | Timer interrupt failure |
18004 | Sync check interrupt failure |
18005 | Parity check interrupt failure |
18006 | Access error interrupt failure |
18012 | Bad checksum error |
18013 | Micro Channel interface error |
18021 | Wizard memory compare or parity error |
18022 | Wizard memory address line error |
18023 | Dynamic RAM controller error |
18029 | Wizard memory byte enable error |
18031 | Wizard memory expansion module memory compare or parity error |
18032 | Wizard memory expansion module byte enable error |
19039 | Wizard memory expansion module byte enable error |
DBCS Japanese Display Adapter
Kód | Popis |
185xx | A fault has occurred with the display adapter - replace the display adapter |
80286 Memory Expansion Option Module
Kód | Popis |
194xx | A fault has occurred with the memory module - replace the memory module |
Image Adapter
Kód | Popis |
200xx | A fault has occurred with the image adapter - replace the image adapter |
Unknown SCSI Device
Kód | Popis |
208xx | A fault has occurred in an unknown SCSI adapter - replace the unknown SCSI adapter |
SCSI Removable Media
Kód | Popis |
209xx | A fault has occurred in the SCSI removable disk - replace the removable disk |
SCSI Fixed Disk
Kód | Popis |
210PLSC | "PLSC" codes indicate errors |
P = SCSI ID number (Physical Unit Number or PUN) | |
L = Logical unit number (LUN, usually 0) | |
S = Host adapter slot number | |
C = SCSI drive capacity | |
A = 60MB | |
B = 80MB | |
C = 120MB | |
D = 160MB | |
E = 320MB | |
F = 400MB | |
H = 1.02MB (1GB) | |
I = 104MB | |
J = 212MB | |
U = Undetermined or non IBM OEM drive |
SCSI Tape Drive
Kód | Popis |
211xx | A fault has occurred with the SCSI tape drive - replace the SCSI tape drive |
SCSI Printer
Kód | Popis |
212xx | A fault has occurred with the SCSI printer - replace the SCSI printer |
SCSI Processor
Kód | Popis |
213xx | A fault has occurred with the SCSI adapter processor - replace the SCSI adapter |
SCSI Write Once Read Multiple (WORM) Drive
Kód | Popis |
214xx | A fault has occurred with the SCSI WORM drive - replace the SCSI WORM drive |
SCSI CD-ROM Drive
Kód | Popis |
215xx | A fault has occurred with the SCSI CD-ROM drive - replace the SCSI CD-ROM drive |
SCSI Scanner
Kód | Popis |
216xx | A fault has occurred with the SCSI Scanner - replace the SCSI Scanner |
SCSI Magneto Optical Drive
Kód | Popis |
217xx | A fault has occurred with the SCSI Magneto Optical Drive - replace the drive |
SCSI Jukebox Changer
Kód | Popis |
218xx | A fault has occurred with the SCSI Jukebox Changer - replace the device |
SCSI Communications
Kód | Popis |
219xx | A fault has occurred with the SCSI Communications device - replace the device |
XGA-2 Adapter
Kód | Popis |
243xxxx | A fault has occurred with the XGA-2 adapter - replace the adapter |
Dynamic Configuration Select (DCS) Information kódy
Kód | Popis |
I998001x | Bad integrity of DCS master boot record |
I988002x | Read failure of DCS master boot record |
I988003x | DCS master boot record is not compatible with the planar ID |
I988004x | DCS master boot record is not compatible with the model/submodel byte |
I988005x | Bad integrity of CMOS/NVRAM or internal process error |
I988006x | Read failure of header/mask/configuration record |
I988007x | Bad integrity of header/mask/configuration record |
I988008x | Hard disk does not support the command to set the maximum RBA |
I988009x | DCS master boot record is older than system ROM |
I9880402 | Copyright notice in E000 segment does not match the one in DCS MBR |
I9880403 | DCS MBR is not compatible with the system board ID or model/submodel byte |
Initial Microcode Load (IML)
Kód | Popis |
I999001x | Invalid disk IML error |
I999002x | Disk IML record load error |
I999003x | Disk IML record incompatible with system board |
I999004x | Disk IML record incompatible with processor/processor card |
I999005x | Disk IML not attempted |
I999006x | Disk stage II system image load error |
I999007x | Disk stage II image checksum error |
I999008x | IML not supported on primary disk drive |
I999009x | Disk IML record is older than ROM |
I99900x1 | Invalid diskette IML record |
I99900x2 | Diskette IML record load error |
I99900x3 | Diskette IML record incompatible with system board |
I99900x4 | Diskette IML record incompatible with processor board |
I99900x5 | Diskette IML recovery prevented (valid password and CE override not set) |
I99900x6 | Diskette stage II image load error |
I99900x7 | Diskette stage II image checksum error |
I99900x9 | Diskette IML record older then ROM |
No Bootable Device, Initial Program Load (IPL)
Kód | Popis |
I9990301 | Hard disk error |
I9990302 | Invalid disk boot record, unable to read IPL boot record from disk |
I9990303 | IML system partition boot failure |
I9990304 | No bootable device with ASCII console |
I9990305 | No bootable device |
I9990306 | Invalid SCSI Device boot record |
I9990401 | Unauthorized access (manufacturing boot request with valid password) |
I9990402 | Missing ROM IBM copyright notice |
I9990403 | IML Boot record incompatible with system board/processor card |
Microid Research/Mr. BIOS
Chyba |
Popis |
Lock Check | Check if a system lock-byte is set and wait for user response if an error is generated. Check the panel lock or circuitry |
Numlock/Password/Setup | Set Numlock on (if set) and ask for password (if set) and display setup message |
Typematic Rate | Set the typematic rate |
Floppy Disk | Perform any further initialization needed |
Hard Disk | Perform any further initialization needed |
Video Mode | Set primary video mode and display any errors found during initialization routines |
Shadow and Cache Enable | The shadow RAM and cache are enabled |
Adapter ROM | Initialize adapters with a ROM signature of 55AA. Self tests will be performed by the equipment concerned before handing back control to the POST |
Video Monitor Mode | Set the video mode based on the information in the CMOS and update the time variables from the RTC |
Parity/NMI Enable | Enable NMI by setting bit 7 of CMOS address 41 and enable parity. There should be no failures during this |
Set Stack | Set the last significant byte of the stack pointer and install the shadow RAM at E000 if set by CMOS |
Acknowledge | Acknowledge errors and set primary video mode before calling Int 19 bootloader. Errors reported will await a keyboard repines before proceeding. Errors beyond this point are normally software related |
Hlįsenie |
Popis |
Diskette drive A error | Drive A: is present but fails the POST diskette tests. Check that the drive is defined with the proper diskette type in Setup and that the disk is installed correctly |
Extended RAM failed at offset: nnn | Extended memory not working or not configured properly at offset: nnn |
Failing Bits: nnnn | The hexadecimal number nnnn is a map of the bits at the RAM address that failed the memory test. Each 1 in the map indicates a failed bit |
Fixed Disk 0 Failure | Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup to be sure the fixed disk type is correctly identified |
Fixed Disk 1 Failure | Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup to be sure the fixed disk type is correctly identified |
Fixed Disk Controller Failure | Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup to be sure the fixed disk type is correctly identified |
Incorrect Drive A: type - run Setup | Type of diskette for drive A: not correctly identified in Setup |
Invalid NVRAM media type | Problem with NVRAM (CMOS) access |
Keyboard controller error | The keyboard controller failed test. Try replacing the keyboard |
Keyboard error | Keyboard not working |
Keyboard error nn | BIOS discovered a stuck key and displays the scan code nn for the stuck key |
Keyboard locked - Unlock key switch | Unlock the system to proceed |
Monitor type does not match CMOS - Run Setup | Monitor type not correctly identified in Setup |
Operating system not found | Operating system cannot be located on either A: or C:. Enter Setup and see if fixed disk and drive A: are properly identified |
Parity Check 1 | Parity error found in the system bus. BIOS attempts to locate the address and display it on screen. If it cannot locate the address, it displays ??? |
Parity Check 2 | Parity error found in the I/O bus. BIOS attempts to locate the address and display it on screen. If it cannot locate the address, it displays ??? |
Press <F1> to resume, <F2> to Setup | Displayed after any recoverable error message. Press F1 to start the boot process or F2 to enter Setup and change any settings |
Real-time clock error | Real-time clock fails BIOS test. Might require motherboard repair |
Shadow RAM failed at offset: nnnn | Shadow RAM failed at offset nnnn of the 64KB block at which the error was detected |
System battery is dead - Replace and run Setup | The CMOS clock battery indicator shows the battery is dead. Replace the battery and run Setup to reconfigure the system |
System cache error - Cache disabled | RAM cache failed the BIOS test. BIOS disabled the cache |
System CMOS checksum bad - run Setup | System CMOS RAM has been corrupted or modified incorrectly. Perhaps by an application program that changes data stored in CMOS. Run Setup and reconfigure the system either by getting the default values or making your own selections |
System RAM failed at offset: nnnn | System RAM failed at offset nnnn of the 64KB block at which the error was detected |
System timer error | The timer test failed. Requires repair of system motherboard |