Error hlįsenia

Zoznam chybovżch a diagnostickżch hlįsenķ BIOSov

AMI BIOS Text Error hlįsenia

Hlįsenia Explanation
Bad PnP Serial ID Checksum The Serial ID checksum of a PnP card is invalid
Floppy Disk Controller Resource Conflict The floppy drive controller had requested a resource that is already in use
NVRAM Checksum Error - NVRAM Cleared The extended system configuration data (ESCD) was reinitialized because of an NVRAM checksum error.  Clear CMOS and ESCD RAM and reboot
NVRAM Cleared By Jumper The Clear CMOS jumper has been moved to the Clear position.  CMOS RAM and ESCD have been cleared
NVRAM Data Invalid - NVRAM Cleared Invalid data found in the ESCD, which might mean that you have changed devices in the system.  When this message is displayed, the BIOS has already rewritten the ESCD with current configuration data
Parallel Port Resource Conflict The parallel port requested a resource that is already in use
PCI Error Log is Full More than 15 PCI conflict errors have been detected and no additional PCI errors can be logged
PCI I/O Port Conflict Two devices requested the same I/O address, resulting in a conflict
PCI IRQ Conflict Two devices requested the same IRQ, resulting in a conflict
PCI Memory Conflict Two devices requested the same memory resource, resulting in a conflict
Primary Boot Device Not Found Two designated primary boot device (hard disk, floppy disk drive, CD-ROM drive) could not be found
Primary IDE Controller Resource Conflict The primary IDE controller has requested a resource that is already in use
Primary Input Device Not Found The designated primary input device (keyboard, mouse, or other device if input is redirected) could not be found
Secondary IDE Controller Resource Conflict The secondary IDE controller has requested a resource that is already in use
Serial Port 1 Resource Conflict Serial port 1 has requested a resource that is already in use
Serial Port 2 Resource Conflict Serial port 2 has requested a resource that is already in use
Static Device Resource Conflict A card that is not Plug-and-Play ISA has requested a resource that is already in use
System Board Device Resource Conflict A card that is not Plug-and-Play ISA has requested a resource that is already in use
A20 Error Gate A20 on the keyboard controller is not working
Address line Short Error in the address decoding circuitry on the motherboard
CMOS Battery State Low The battery power is low; replace the battery
CMOS Checksum Invalid After CMOS RAM values are saved, a checksum value is generated for error checking.  The previous value is different from the current value
Run Setup CMOS system options not set.  The values stored in CMOS RAM are either corrupt or nonexistent.  Run Setup
CMOS Display Type Mismatch The video type in CMOS RAM does not match the type detected by the BIOS. Run Setup
CMOS Memory Size Mismatch The amount of memory on the motherboard is different from the amount indicated in CMOS RAM.  Run Setup
CMOS Time and Date Not Set run Setup to set the time and date in the CMOS RAM
Diskette Boot Failure The boot disk in drive A: is corrupt.  It cannot be used to boot the system.  Use another boot disk and follow the screen instructions
DMA Error Error in the DMA controller
DMA #1 Error Error in the first DMA controller
DMA #2 Error Error in the second DMA controller
FDD Controller Failure The BIOS cannot communicate with the floppy disk drive controller.   Check all appropriate cables and connections
HDD Controller Failure The BIOS cannot communicate with the hard disk drive controller.   Check all appropriate cables and connections
Insert Bootable Media The BIOS cannot find a bootable medium.  Insert a bootable floppy disk or CD-ROM
INTR #1 Error Interrupt controller 1 failed POST
INTR #2 Error Interrupt controller 2 failed POST
Invalid Boot Diskette The BIOS can read the disk in floppy drive A:, but cannot boot the system from it.  Use another boot disk
KB/Interface Error There is an error in the keyboard connector
Keyboard Error There is a timing problem with the keyboard
Keyboard Stuck Key Detected A stuck keyboard key was detected
Off Board Parity Error Parity error in memory installed in an expansion slot.  The format is: OFF BOARD PARITY ERROR ADDR (HEX) = (XXXX), where XXXX is the hex address where the error occurred
On Board Parity Error Parity error in memory installed on the motherboard.  The format is: ON BOARD PARITY ERROR ADDR (HEX) = (XXXX), where XXXX is the hex address where the error occurred
Parity Error Parity error in system memory at an unknown address
System halted An error caused the computer to halt
Timer Channel 2 Error There is an error in counter/timer 2
Uncorrectable ECC Error An uncorrectable ECC memory error was detected
Undetermined NMI An undetermined NMI was detected
Memory parity Error at xxxxx Memory failed.  If the memory location can be determined, it is displayed as xxxxx.  If not, the message is Memory Parity Error ????.
I/O Card Parity Error at xxxxx An expansion card failed.  If the address can be determined, it is displayed as xxxxx.  if not, the message is I/O Card Parity error ????
DMA Bus Timeout A device has driven the bus signal for more than 7.8 microseconds

AMI BIOS  - Pre BIOS  Feb. 1991:

Hlįsenie

Popis
NMI Disable NMI interrupt line to the CPU is disabled by setting bit 7 I?O port 70h (CMOS)
Power On Delay Once the keyboard controller gets power, it sets the hard and soft reset bits.  Check the keyboard controller or clock generator if a failure occurs
Initialize Chipsets Check the BIOS, CLOCK and chipsets
Reset Determination The BIOS reads the bits in the keyboard controller to see if a hard or soft reset is required (a soft reset will not test memory above 64K).  Failure could be the BIOS or keyboard controller
ROM BIOS Checksum The BIOS performs a checksum on itself and adds a preset factory value that should make it equal to 00.  If a failure occurs, check the BIOS chips
Keyboard Test A command is sent to the 8042 keyboard controller which performs a test and sets a buffer space for commands.  After the buffer is defined the BIOS sends a command byte, writes data to the buffer, checks the high order bits of the internal keyboard controller and issues a No Operation (NOP) command
CMOS Shutdown byte in CMOS RAM offset 0F is tested, the BIOS checksum calculated and diagnostic byte 0E updated before the CMOS RAM area is initialized and updated for date and time.  Check the RTC and CMOS chip or battery if a failure occurs
DMA (8237) and PIC (8259) Disable The DMA and Programmable Interrupt Controller are disabled before the POST proceeds and further.  Check the 8237 or 8259 chips if a failure occurs
Video Disable The video controller is disabled and port B initialized.  Check the video adapter if a failure occurs
Chipset Initialized and Memory Detected Memory addressed in 64K blocks.   Failure would be in the chipset.  If all memory is not seen, failure could be in a chip in the block after the last one seen
PIT Test The timing functions of the 8254 Programmable Interrupt Timer are tested.  The PIT and RTC chips normally cause errors here
Memory Refresh PIT's ability to refresh memory is tested.  If an XT, DMA controller #1 handles this.  Failure is normally the PIT (8254) in AT's or the 8237, DMA #1, in XT's
Address Line Test the address lines in the first 64K of RAM.  If a failure occurs, an address line may be the problem
Base 64K Data patterns are written to the first 64K of RAM, unless there is a bad RAM chip in which case you will get a failure
Chipset Initialization The PIT, PIC and DMA controllers are initialized
Set Interrupt Table Interrupt vector table used by PIC is installed in low memory, the first 2K
8042 Keyboard Controller Check The BIOS reads the buffer area in the keyboard controller I/O port 60.  Failure here is normally the keyboard controller
Video Tests The type of video adapter is checked for, then a series of tests are performed on the adapter and monitor
BIOS Data Area The vector table is checked for proper operation and video memory verified before protected mode tests are entered into.   This is done so that any errors found are displayed on the monitor
Protected Mode Tests Perform reads and writes to all memory locations below 1MB.  Failure at this point indicate a bad RAM chip, the 8042 Keyboard Controller or a data line
DMA Chips The DMA registers are tested using a data pattern
Final Initialization these differ with each version.   Typically, the floppy and hard drives are tested and initialized and a check is made for serial and parallel devices.  The information gathered is then compared against the contents of the CMOS and you will see the results of any failures on the monitor
BOOT The BIOS hands over control to the Int 19 bootloader.  This is where you would see error messages such as non-system disk

AWARD BIOS Text Error hlįsenia:

Hlįsenia

Popis
BIOS ROM checksum error - System halted The checksum of the BIOS code in the BIOS chip is incorrect, indicating the BIOS code may have become corrupt.  Replace the BIOS
CMOS battery failed CMOS battery is no longer functional.   Replace the battery
CMOS checksum error - Defaults loaded Checksum of CMOS is incorrect, so the system loads the default values.  A checksum error may indicate that CMOS has become corrupt.  This error might have been caused by a weak battery
CMOS CHECKSUM ERROR DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER Checksum of CMOS is incorrect.    This can indicate that CMOS has become corrupt.  This error may have been caused by a weak CMOS battery
CPU at nnn Displays the running speed of the CPU
DISKETTE DRIVES OR TYPES MISMATCH ERROR - RUN SETUP Type of diskette drive installed in the system is different from the CMOS definition.  Run Setup to reconfigure the drive type correctly
Display switch is set incorrectly The display switch on the motherboard can be set to either monochrome or color.  This message indicates the switch is set to a different setting than indicated in Setup.  Determine which setting is correct and then either turn off the system and change the jumper or enter Setup and change the video selector
DISPLAY TYPE HAS CHANGED SINCE LAST BOOT Since last powering off the system, the display adapter has been changed.  You must configure the system for the new display type
EISA Configuration Checksum Error The EISA nonvolatile RAM checksum is incorrect or cannot correctly read the EISA slot.  This can indicate either the EISA nonvolatile memory has become corrupted or the slot has been configured incorrectly.   Also, be sure the card in installed firmly in the slot
EISA Configuration Is Not Complete The slot configuration information stored in the EISA nonvolatile memory is incomplete
ERROR ENCOUNTERED INITIALIZING HARD DRIVE Hard drive cannot be initialized.   Be sure the adapter is installed correctly and all cables are correctly and firmly attached.  Also be sure the correct hard drive type is selected in Setup
ERROR INITIALIZING HARD DISK CONTROLLER Cannot initialize controller.  Make sure the card is correctly and firmly installed in the bus.  Be sure the correct hard drive type is installed in Setup.  Also check to see if any jumper needs to be set correctly on the hard drive
FLOPPY DISK CONTROLLER ERROR OR NO CONTROLLER PRESENT Cannot find or initialize the floppy disk controller.  make sure the controller is installed correctly and firmly.   If there are no floppy drives installed, be sure the Diskette Drive selection in Setup is set to None
Floppy disk(s) fail Cannot find or initialize the floppy drive controller or the drive.  make sure the controller is installed correctly.   If no floppy drives are installed, be sure the Diskette Drive selection in Setup is set to None or Auto
HARD DISK initializing Please wait for a moment... Some hard drives require some extra time to initialize
HARD DISK INSTALL FAILURE Cannot find or initialize the hard drive controller or the drive.  Make sure the controller is installed correctly.  If no hard drives are installed, be sure the Hard Drive selection in Setup is set to None
Hard disk(s) diagnosis fail The system may run specific disk diagnostic routines.  this message appears if one or more hard disks return an error when the diagnostics run
Invalid EISA Configuration The nonvolatile memory containing EISA configuration information was programmed incorrectly or has become corrupt.  Rerun EISA configuration utility to correctly program the memory
Keyboard error or no keyboard present Cannot initialize the keyboard.   Make sure the keyboard is attached correctly and no keys are being pressed during the boot.  If you are purposely configuring the system without a keyboard, set the error halt condition in Setup to HALT ON ALL, BUT KEYBOARD.  This will cause the BIOS to ignore the missing keyboard and continue the boot
Keyboard is locked out - Unlock the key This message usually indicates that one or more keys have been pressed during the keyboard tests.  Be sure no objects are resting on the keyboard
Memory Address Error at... Indicates a memory address error at a specific location.  You can use this location along with the memory map for your system to find and replace the bad memory chips
Memory parity Error at... Indicates a memory parity error at a specific location.  You can use this location along with the memory map for your system to find and replace the bad memory chips.
MEMORY SIZE HAS CHANGED SINCE LAST BOOT Memory has been added or removed since the last boot.  In EISA mode, use configuration utility to reconfigure the memory configuration.  In ISA mode,enter Setup and enter the new memory size in the memory field
Memory Test The message displays during a full memory test, counting down the memory areas being tested
Memory Test Fail If POST detects an error during memory testing, additional information appears giving specifics about the type and location of the memory error
Memory Verify Error at... Indicates an error verifying a value already written to memory.  Use the location along with your system's memory map to locate the bad chip
No boot device was found This could mean that either a boot device was not detected or the drive does not contain proper system boot files.   Insert a system disk into drive A: and press Enter.  If you assumed the system would boot from the hard drive, make sure the controller is inserted correctly and all cables are properly attached.  Also be sure the disk is formatted as a boot device.   Then reboot the system
OFFENDING ADDRESS NOT FOUND The message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY ERROR messages when the segment that has caused the problem cannot be isolated
OFFENDING SEGMENT: This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY ERROR messages when the segment that has caused the problem has been isolated
Override enabled - Defaults loaded If the system cannot boot using the current CMOS configuration, the BIOS can override the current configuration with a set of BIOS defaults designed for the most stable, minimal-performance system operations
PRESS A KEY TO REBOOT This will be displayed at the bottom of the screen when an error occurs that requires you to reboot.  Press any key to reboot the system
Press ESC to skip memory test You can press ESC to skip the full memory test
PRESS F1 TO DISABLE NMI, F2 TO REBOOT When BIOS detects a non-maskable interrupt condition during boot, this will allow you to disable the NMI and continue to boot; or you can reboot the system with the NMI enabled
Press TAB to show POST screen System OEM's may replace the Award BIOS POST display with their own proprietary display.  Including this message in the OEM display permits the operator to switch between the OEM display
Primary master hard disk fail POST detects an error in the primary master IDE hard drive
Primary slave hard disk fail POST detects an error in the secondary master IDE hard drive
RAM PARITY ERROR - CHECKING FOR SEGMENT... Indicates a parity error in RAM
Resuming from disk, Press TAB to show POST screen Award offers a save-a-disk feature for notebook computers.  This message may appear when the operator restarts the system after a save-to-disk shutdown.  See the Press Tab...message earlier for a description of this feature
Secondary master hard disk fail POST detects an error in the secondary master IDE hard drive
Secondary slave hard disk fail POST detects an error in the secondary slave IDE hard drive
Should Be Empty But EISA Board Found A valid board ID was found in a slot that was configured as having no board ID
Should Have EISA Board But Not Found The board installed is not responding to the ID request, or no board ID has been found in the indicated slot
Slot Not Empty Indicates that a slot designated as empty by the EISA configuration utility actually contains a board
SYSTEM HALTED. (CTRL-ALT-DEL) TO REBOOT... Indicates the present boot attempt has been aborted and the system must be rebooted.  Press and hold down the Ctrl and Alt keys and press Del
Wrong Board In Slot The board ID does not match the ID stored in the EISA nonvolatile memory


Compaq

Microprocessor Test Error kódy
Kód Popis
0101-xx CPU test failure
0102-xx Coprocessor test failure
0103-xx DMA controller failure
0104-xx Interrupt controller failed
0105-xx Port error
0106-xx Keyboard controller self test failed
0107-xx CMOS RAM test failed
0108-xx CMOS interrupt test failed
0109-xx CMOS clock test failed
0110-xx Programmable interrupt timer failure
0113-01 Protected mode test failed
0114-01 Speaker test failed

Memory Test Error kódy

Kód Popis
0200-xx Memory machine ID test failure
0202-xx Memory system ROM checksum failure
0203-xx Memory read/write test failure
0204-xx Memory address test failure
0205-xxx Memory walking 1's test failure
0209-xxx RAM long test failure
0211-xx Random pattern test failure
0212-xxx Cache test failure
0214-xx Noise test failure
0215-xx Random address test failure

Keyboard Test Error kódy

Kód Popis
0300-xx Keyboard ID test failure
0301-xx Keyboard self test/interface test failure
0302-xx Individual key test failure
0304-xx Keyboard repeat test failure

Parallel Printer Test Error kódy

Kód Popis
0401-xx Printer failure or not connected
0402-xx Printer port test failure
0403-xx Printer pattern test failure

Diskette Drive Test Error kódy

Kód Popis
0600-xx Diskette ID drive types test failure
0601-xx Diskette format failure
0602-xx Diskette read test failure
0603-xx Diskette write, read, compare test failure
0604-xx Diskette random seek test failure
0605-xx Diskette ID media test failure
0606-xx Diskette speed test failure
0607-xx Diskette change line test failure

Serial Port Test Error kódy

Kód Popis
1101-xx Serial port test failed

Modem Communications Test Error kódy

Kód Popis
1201-xx Modem internal test failure
1203-xx Modem external termination test failure
1204-xx Modem auto originate test failure
1205-xx Modem auto answer test failure
1210-xx Modem direct connect test failure

Hard Drive Test Error kódy

Kód Popis
1701-xx Hard drive format test failure
1702-xx Hard drive read test failure
1703-xx hard drive write/read/compare test failure
1704-xx Hard drive random seek test failure
1705-xx Hard drive controller test failure
1708-xx Hard drive format bad track test failure
1710-xx Hard drive park head test failure
1715-xx Hard drive head select test failure
1716-xx Hard drive conditional format test failure
1717-xx Hard drive ECC test failure
1719-xx Hard drive power mode test failure
1724-xx Hard drive network preparation test failure
1736-xx Hard drive monitoring test failure

Tape Drive Test Error kódy

Kód Popis
1900-xx Tape drive ID test failure
1901-xx Tape drive servo test failure
1902-xx Tape drive format or format verification test failure
1903-xx Tape sensor test failure
1904-xx Tape drive BOT/EOT test failure
1905-xx Tape drive read test failure
1906-xx Tape drive write/read/compare failure
1910-xx Tape erase test failure

Video Test Error kódy

Kód Popis
2401-xx Graphics controller test failure
2402-xx Video memory test failure
2403-xx Video attribute test failure
2404-xx Video character set test failure
2405-xx Video 80 x 25 mode 9 x 14 character cell test failure
2506-xx Video 80 x 25 mode 8 x 8 character cell test failure
2408-xx Video 320 x 200 mode color set 0 test failure
2409-xx Video 320 x 200 mode color set 1 test failure
2410-xx Video 640 x 200 mode test failure
2411-xx Video screen memory page test failure
2412-xx Video gray scale test failure
2418-xx ECG/VGC memory test failure
2419-xx ECG/VGC ROM checksum test failure
2420-xx Graphics attribute test failure
2421-xx ECG/VGC 640 x 200 graphics mode test failure
2422-xx ECG/VGC 640 x 350 16 color set test failure
2423-xx ECG/VGC 640 x 350 64 color set test failure
2424-xx ECG/VGC monochrome text mode test failure
2425-xx ECG/VGC monochrome graphics mode test failure
2431-xx 640 x 480 graphics test failure
2432-xx 320 x 200 graphics (245 color mode) test failure
2448-xx Advanced VGA controller test failure
2451-xx 132 column advanced VGA test failure
2456-xx Advanced VGA 256 color test failure
2458-xx Advanced VGA BitBLT test failure
2468-xx Advanced VGA DAC test failure
2477-xx Advanced VGA data path test failure
2478-xx Advanced VGA BitBLT test failure
2480-xx Advanced VGA linedraw test failure

Audio Test Error kódy

Kód Popis
3206-xx Audio system internal error

Network Interface Test Error kódy

Kód Popis
6000-xx Network ID test failure
6014-xx Network configuration test failure - Ethernet
6016-xx Network reset test failure - Ethernet
6028-xx Network internal test failure - Ethernet
6029-xx Network external test failure - Ethernet
6054-xx Network configuration test failure - Token ring
6056-xx Network reset test failure - Token ring
6068-xx Network internal test failure - Token ring
6069-xx Network external test failure - Token ring
6089-xx Network open test failure - Token ring

SCSI CD-ROM Test Error kódy

Kód Popis
6600-xx ID test failure
6605-xx Read test failure
6608-xx Controller test failure
6623-xx Random read test failure

SCSI Test Error kódy

Kód Popis
65xx-xx Hard drive related error
66xx-xx CD-ROM Drive or PD-CD drive related error
67xx-xx Tape drive related error
xx00-xx ID based error code
xx05-xx Read based error code
xx06-xx SA/Media based error code
xx08-xx Controller based error code
xx09-xx Media erase based error code
xx23-xx Random read based error code
xx-28-xx Media load/unload based error code
xxxx-02 Drive not installed
xxxx-03 Media not in drive
xxxx-05 Seek failure
xxxx-06 Drive timed out
xxxx-07 Drive busy
xxxx-08 Drive already reserved
xxxx-09 Unknown
xxxx-10 Unknown
xxxx-11 Media soft error
xxxx-12 Drive not ready
xxxx-13 Media error
xxxx-14 Drive hardware error
xxxx-15 Illegal drive command
xxxx-16 Media has changed
xxxx-17 Tape write protect
xxxx-18 No data detected
xxxx-21 Drive command aborted
xxxx-24 Media hard error
65xx-24 Media hard error
66xx-24 Media hard error
67xx-24 Media hard error
xxxx-25 Unknown
xxxx-30 Controller timed out
xxxx-31 Unrecoverable error
xxxx-32 Controller/drive disconnected
xxxx-33 Illegal controller command
xxxx-34 Invalid SCSI bus phase
xxxx-35 Invalid SCSI bus phase
xxxx-36 Invalid SCSI bus phase
xxxx-39 Error status from drive
xxxx-40 Target timed out
xxxx-41 SCSI bus stayed busy
xxxx-42 ACK/REQ lines bad
xxxx-43 ACK did not deassert
xxxx-44 Parity error
xxxx-50 Data pins bad
xxxx-51 Data line 7 bad
xxxx-52 MSG, C/D, and/or I/O lines bad
xxxx-53 BSY never went busy
xxxx-54 BSY stayed busy
xxxx-60 Controller CONFIG-1 register bad
xxxx-61 Controller CONFIG-2 register bad
xxxx-65 Media not loaded
xxxx-90 Fan failure
xxxx-91 Over temperature
xxxx-99 Autoloader reported tapes not loaded properly

Pointing Device Test Error kódy

Kód Popis
8601-xx Mouse test failed
8602-xx Interface test failed

 

IBM Diagnostic Error kódy
 
System Board
 
Kód Popis
101 System board interrupt failure (unexpected interrupt)
102 BIOS ROM checksum error (PC, XT); timer error (AT, MCA)
103 BASIC ROM checksum error (PC, XT); timer interrupt error (AT, MCA)
104 Interrupt controller error (PC, XT); protected mode error (AT, MCA)
105 Timer failure (PC, XT); 8042 keyboard controller failure (MCA)
106 System board converting logic test failure
107 System board non-maskable interrupt (NMI) test failure; Hot NMI test failure (MCA)
108 System board timer bus test failure
109 DMA test memory select failure
110 PS/2 system board parity check error (MCA); PS/2 system board memory error (ISA)
111 PS/2 adapter memory problem (ISA); PS/2 I/O channel parity check error (MCA)
112 PS/2 watchdog timeout error (NMI)
113 PS/2 DMA arbitration time out error (NMI)
114 PS/2 external ROM checksum error
115 BIOS ROM checksum error, cache parity error, or DMA error
116 System board read/write error
118 System Board parity or L2 cache error
119 2.88MB floppy installed but not supported by the floppy controller
120 CPU self test error
121 Unexpected hardware interrupt occurred; 256KB ROM checksum error (second 128KB bank)
129 System Board Failure
131 Cassette wrap test; DMA compatibility registers error
132 DMA extended registers error
133 DMA verify logic error
134 DMA arbitration error
151 Battery, real time clock, or CMOS RAM failure
152 Real time clock, or CMOS RAM failure
160 PS/2 system board ID not recognized
161 CMOS configuration lost (battery has died)
162 CMOS checksum error, CRC error, or adapter ID mismatch
163 CMOS error; Clock is not updating
164 CMOS error; CMOS setting does not match memory on system board
165 PS/2 adapter ID mismatch
166 PS/2 adapter time out; card busy
167 PS/2 system clock not updating
168 Math coprocessor error in the CMOS configuration
169 System board and processor card configuration mismatch
170 ASCII setup conflict error
171 Rolling bit test failure on CMOS shutdown byte
172 Rolling bit test failure on NVRAM diagnostic byte
173 Bad CMOS/NVRAM checksum
174 Bad system configuration
175 Bad EEPROM CRC
177 Bad password CRC
178 Bad EEPROM
179 NVRAM error log full
180x Sub address date error in slot x
181 Unsupported configuration
182 Password switch is not in the writing position
183 System halted; password is required
184 Bad power on password
185 Bad startup sequence
186 Password protection hardware error
187 Serial number error
188 Bad EEPROM checksum
189 Too many incorrect password attempts
191 Cache controller test failed
194 System board memory error
195 Configuration read from hibernation area of HDD doesn't match actual configuration
196 Read error occurred in hibernation area of HDD
199 User indicated device list not correct

Memory

Kód Popis
20x Memory error
201 Memory test failure; error location might be displayed
202 Memory address error; lines 00-15
203 Memory address error; lines 16-23 (ISA) or 16-31 (MCA)
204 Memory remapped due to error (run diagnostics again)
205 Base 128KB memory error; memory remapped
207 ROM failure
210 System board memory parity error
211 Error in first 64KB of RAM
212 Watchdog timer error
213 DMA bus arbitration time out
215 Memory address error; 64KB on daughter/SIP 2 failed
216 Memory address error; 64KB on daughter/SIP 1 failed
221 ROM to RAM copy failed
225 Wrong speed memory on system board
229 Memory Error
230 Overlapping adapter and planar memory
231 Non continuous adapter memory installed
235 Stuck data line on memory module
241 Memory module 2 failed
251 Memory module 3 failed

Keyboard

Kód Popis
301 Keyboard did not respond correctly
302 Keyboard locked
303 Keyboard and/or system board interface error; keyboard controller fault
304 Keyboard or system unit error
305 Keyboard fuse failed on system board
306 Unsupported keyboard attached
341 Keyboard error
342 Keyboard cable error
343 Enhancement card or cable error
365 Keyboard failure
366 Interface cable failure
367 Enhancement card or cable failure

Monochrome Display Adapter

Kód Popis
401 Memory, horizontal sync frequency or vertical sync failure
408 User indicated display attribute failure
416 User indicated character set failure
424 User indicated 80 x 25 mode failure
432 MDA card parallel port test failure

Color Graphics Adapter

Kód Popis
501 CRT error; CGA memory, horizontal sync frequency or video test failure
503 CGA adapter controller failed
508 User display attribute failure
516 User indicated character set failure
524 User indicated 80 x 25 mode failure
532 User indicated 40 x 25 mode failure
540 User indicated 320 x 200 graphics mode failure
548 User indicated 640 x 200 graphics mode failure
556 User indicated light pen test failed
564 User indicated paging test failure

Floppy Drive/Controller

Kód Popis
601 General diskette or adapter failure
602 Diskette boot sector is not valid
603 Diskette size error
604 Media sense error
605 Diskette drive locked
606 Diskette verify test failed
607 Write protect error
608 Drive command error
610 Diskette initialization failure
611 Drive time out error
612 NEC drive controller IC error
613 Floppy system DMA error
614 Floppy system DMA boundary overrun error
615 Drive index timing error
616 Drive speed error
621 Drive seek error
622 Drive cyclic redundancy check (CRC) error
625 Controller chip (NEC) seek error
626 Diskette data compare error
627 Diskette data compare error
628 Diskette removed
630 Index stuck high; drive A:
631 Index stuck low; drive A:
632 Track 0 stuck off; drive A:
632 Track 0 stuck on; drive A:
640 Index stuck high; drive B:
641 Index stuck low; drive B:
642 Track 0 stuck off; drive B:
643 Track 0 stuck on; drive B:
645 No index pulse
646 Drive track 0 detection failed
647 No transitions on read data line
648 Format test failed
649 Incorrect media type in drive
650 Drive speed error
651 Format failure
652 Verify failure
653 Read failure
654 Write failure
655 Controller error
656 Drive failure
657 Write protect stuck protected
658 Changeline stuck unprotected
659 Write protected stuck unprotected
660 Changeline stuck unchanged

Math Coprocessor

Kód Popis
701 Math coprocessor presence/initialization error
702 Exception errors test failure
703 Rounding test failure
704 Arithmetic test 1 failure
705 Arithmetic test 2 failure
706 Arithmetic test 3 failure; Test is performed on 80387 only
707 Combination test failure
708 Integer load/store test failure
709 Equivalent expressions errors
710 Interrupt errors
711 Save state errors
712 Protected mode test failure
713 Voltage test failure

Parallel Printer Adapter

Kód Popis
901 Data register latch error
902 Control register latch error
903 Register address decode error
904 Address decode error
910 Status line wrap connector error
911 Status line bit 8 wrap error
912 Status line bit 7 wrap error
913 Status line bit 6 wrap error
914 Status line bit 5 wrap error
915 Status line bit 4 wrap error
916 Printer adapter interrupt wrap error
917 Unexpected printer adapter interrupt
92x Feature register error

Alternate Printer Adapter

Kód Popis
1001 Printer adapter data register latch error
1002 Printer adapter control register latch error
1003 Printer adapter register address decode error
1004 Printer adapter address decode error
1010 Status line wrap connector error
1011 Status line bit 8 wrap error
1012 Status line bit 7 wrap error
1013 Status line bit 6 wrap error
1014 Status line bit 5 wrap error
1015 Status line bit 4 wrap error
1016 Printer adapter interrupt wrap error
1017 Unexpected printer adapter interrupt
102x Feature register error

Primary Async Communications

Kód Popis
1101 16450/16550 chip error; serial port A error
1102 Card selected feedback error; PC convertible internal modem test failed
1103 Port 102h register test failure; PC convertible internal modem dial tone test 1 failed
1104 PC convertible internal modem dial tine test 2 failed
1106 Serial option cannot be put to sleep
1107 Cable error
1108 Interrupt request (IRQ) 3 error
1109 Interrupt request (IRQ) 4 error
1110 16450/16550 chip register failure
1111 Internal wrap test of 16450/16550 chip modem control line failure
1112 External wrap test of 16450/16550 chip modem control line failure
1113 16450/16550 chip transmit error
1114 16450/16550 chip receive error
1115 16450/16550 chip receive error; data not equal to transmit data
1116 16450/16550 chip interrupt function error
1117 16450/16550 chip baud rate test failure
1118 16450/16550 chip receive external data wrap test failure
1119 16550 chip first-in/first-out (FIFO) buffer failure
1120 Interrupt enable register error; all bits cannot be set
1121 Interrupt enable register error; all bits cannot be reset
1122 Interrupt pending; stuck on
1123 Interrupt ID register; stuck on
1124 Modem cannot register error; all bits cannot be set
1125 Modem cannot register error; all bits cannot be reset
1126 Modem status register error; all bits cannot be set
1127 Modem status register error; all bits cannot be reset
1128 Interrupt ID error
1129 Cannot force overrun error
1130 No modem status interrupt
1131 Invalid interrupt pending
1132 No data ready
1133 No data available interrupt
1134 No transmit holding interrupt
1135 No interrupts
1136 No received line status interrupt
1137 No receive data available
1138 Transmit holding register not empty
1139 No modem status interrupt
1140 Transmit holding register not empty
1141 No interrupts
1142 No interrupt 4
1143 No interrupt 3
1144 No data transferred
1145 Maximum baud rate error
1146 Minimum baud rate error
1148 Time out error
1149 Invalid data returned
1150 Modem status register error
1151 No data set ready and delta data set ready
1152 No data set ready
1153 No delta data set ready
1154 Modem status register not clear
1155 No clear to send and delta clear to send
1156 No clear to send
1157 No delta clear to send

Alternate Async Communications

Kód Popis
1201 16450/16550 chip error
1202 Card selected feedback error
1203 Port 02h register test failure
1206 Serial option cannot be put to sleep
1207 Cable error
1208 Interrupt request (IRQ) 3 error
1209 Interrupt request (IRQ) 4 error
1210 16450/16550 chip register failure
1211 Internal wrap test of 16450/16550 chip modem control line failure
1212 External wrap test of 16450/16550 chip modem control line failure
1213 16450/16550 chip transmit error
1214 16450/16550 chip receive error
1215 16450/16550 chip receive error; data not equal to transmit data
1216 16450/16550 chip interrupt function error
1217 16450/16550 chip baud rate test failure
1218 16450/16550 chip receive external data wrap test failure
1219 16550 chip first-in/first-out (FIFO) buffer failure
1220 Interrupt enable register error; all bits cannot be set
1221 Interrupt enable register error; all bits cannot be reset
1222 Interrupt pending; stuck on
1223 Interrupt ID register; stuck on
1224 Modem cannot register error; all bits cannot be set
1225 Modem cannot register error; all bits cannot be reset
1226 Modem status register error; all bits cannot be set
1227 Modem status register error; all bits cannot be reset
1228 Interrupt ID error
1229 Cannot force overrun error
1230 No modem status interrupt
1231 Invalid interrupt pending
1232 No data ready
1233 No data available interrupt
1234 No transmit holding interrupt
1235 No interrupts
1236 No received line status interrupt
1237 No receive data available
1238 Transmit holding register not empty
1239 No modem status interrupt
1240 Transmit holding register not empty
1241 No interrupts
1242 No interrupt 4
1243 No interrupt 3
1244 No data transferred
1245 Maximum baud rate error
1246 Minimum baud rate error
1248 Time out error
1249 Invalid data returned
1250 Modem status register error
1251 No data set ready and delta data set ready
1252 No data set ready
1253 No delta data set ready
1254 Modem status register not clear
1255 No clear to send and delta clear to send
1256 No clear to send
1257 No delta clear to send

Game Control Adapter

Kód Popis
1301 Game control adapter test failure
1302 Joystick test failure

Matrix Printer

Kód Popis
1401 Printer test failure
1402 Printer not ready, not on line, or out of paper
1403 Printer no paper error
1404 Matrix printer test failure; system board time out
1405 Parallel adapter failure
1406 Printer presence test failed

Synchronous Data Link Control Communications (SDLC) Adapter

Kód Popis
1501 SDLC adapter test failure
1510 8255 port B failure
1511 8255 port A failure
1512 8255 port C failure
1513 8253 timer #1 did not reach terminal count
1514 8253 timer #1 stuck on
1515 8253 timer #0 did not reach terminal count
1516 8253 timer #0 stuck on
1517 8253 timer #2 did not reach terminal count
1518 8253 timer #2 stuck on
1519 8273 port B error
1520 8273 port A error
1521 8273 command/read time out
1522 Interrupt level 4 failure
1523 Ring indicate stuck on
1524 Receive clock stuck on
1525 Transmit clock stuck on
1526 Test indicate stuck on
1527 Ring indicate stuck on
1528 Receive clock stuck on
1529 Transmit clock stuck on
1530 Test indicate not on
1531 Data set ready not on
1532 Carrier detect not on
1533 Clear to send not on
1534 Data set ready stuck on
1535 Carrier detect stuck on
1536 Clear to send stuck on
1537 Interrupt level 3 failure
1538 Receive interrupt results error
1539 Wrap data compare error
1540 Direct memory access channel 1 error
1541 Direct memory access channel 1 error
1542 8273 error checking or status reporting error
1547 Stray interrupt level 4
1548 Stray interrupt level 3
1549 Interrupt presentation sequence time out

Display Station Emulation Adapter (DSEA)

Kód Popis
1604 DSEA or twinaxial network error
1608 DSEA or twinaxial network error
1624 DSEA error
1634 DSEA error
1644 DSEA error
1652 DSEA error
1654 DSEA error
1658 DSEA error
1662 DSEA interrupt level error
1664 DSEA error
1668 DSEA interrupt level error
1669 DSEA diagnostics error; use 3.0 or higher
1674 DSEA diagnostics error; use 3.0 or higher; DSEA station address error
1684 DSEA device address error
1688 DSEA device address error

Hard Drive and Controller

Kód Popis
1701 Fixed disk or adapter general error
1702 Drive and controller time out error
1703 Drive seek error
1704 Drive controller failed
1705 Drive sector not found error
1706 Write fault error
1707 Drive track 00 error
1708 Head select error
1709 Bad ECC returned
1710 Sector buffer overrun
1711 Bad address mark
1712 Internal controller diagnostics failure
1713 Data compare error
1714 Drive not ready
1715 Track 00 indicator error
1716 Diagnostics cylinder errors
1717 Surface read errors
1718 Hard drive error
1720 Bad diagnostics cylinder
1726 Data compare error
1730 Drive controller error
1731 Drive controller error
1732 Drive controller error
1733 BIOS undefined error return
1735 Bad command error
1736 Data corrected error
1737 Bad drive track error
1738 Bad sector error
1739 Bad initialization error
1740 Bad sense error
1750 Drive verify error
1751 Drive read error
1752 Drive write error
1753 Drive random read test failure
1754 Drive seek test failure
1755 Drive controller failure
1756 Controller ECC test failure
1757 Controller head select failure
1780 Drive seek failure (drive 0)
1781 Drive seek failure (drive 1)
1782 Hard disk controller failure
1790 Diagnostic cylinder read error (drive 0)
1791 Diagnostic cylinder read error (drive 1)

I/O Expansion Unit

Kód Popis
1801 Expansion unit POST error
1810 Enable/Disable failure
1811 Extender card wrap test failure while disabled
1812 High order address lines failure while disabled
1813 Wait state failure while disabled
1814 Enable/disable could not be set on
1815 Wait state failure while enabled
1816 Extender card wrap test failure while enabled
1817 High order address lines failure while enabled
1818 Disable not functioning
1819 Wait request switch not set correctly
1820 Receiver card wrap test failed
1821 Receiver high order address lines failure

Binary Synchronous Communications (BSC) Adapter

Kód Popis
2001 BSC adapter test failure
2010 8255 port A failure
2011 8255 port B failure
2012 8255 port C failure
2013 8253 timer #1 did not reach terminal count
2014 8253 timer #1 stuck on
2015 8253 timer #2 did not reach terminal count
2016 8253 timer #2 stuck on
2017 8251 data set ready failed to come on
2018 8251 clear to send not sensed
2019 8251 data set ready stuck on
2020 8151 clear to send stuck on
2021 8151 hardware reset failure
2022 8251 software reset failure
2023 8251 software "error reset" failure
2024 8251 transmit ready did not come on
2025 8251 receive ready did not come on
2026 8251 could not force "overrun" error status
2027 Interrupt failure; no timer interrupt
2028 Interrupt failure; transmit; replace card or planar
2029 Interrupt failure; transmit; replace card
2030 Interrupt failure; receive; replace card or planar
2031 Interrupt failure; receive; replace card
2033 Ring indicate stuck on
2034 Receive clock stuck on
2035 transmit clock stuck on
2036 Test indicate stuck on
2037 Ring indicate stuck on
2038 Receive clock not on
2039 Transmit clock not on
2040 Test indicate not on
2041 Data set ready not on
2042 Carrier detect not on
2043 Clear to send not on
2044 Data set ready stuck on
2045 Carrier detect stuck on
2046 Clear to send stuck on
2047 Unexpected transmit interrupt
2048 Unexpected receive interrupt
2050 8251 detected overrun error
2051 Lost data set ready during data wrap
2052 Receive time out during data wrap

Alternate Binary Synchronous Communications (BSC) Adapter

Kód Popis
2101 BSC adapter test failure
2110 8255 port A failure
2111 8255 port B failure
2112 8255 port C failure
2113 8253 timer #1 did not reach terminal count
2114 8253 timer #1 stuck on
2115 8253 timer #2 did not reach terminal count
2116 8253 timer #2 stuck on
2117 8251 data set ready failed to come on
2118 8251 clear to send not sensed
2119 8251 data set ready stuck on
2120 8151 clear to send stuck on
2121 8151 hardware reset failure
2122 8251 software reset failure
2123 8251 software "error reset" failure
2124 8251 transmit ready did not come on
2125 8251 receive ready did not come on
2126 8251 could not force "overrun" error status
2127 Interrupt failure; no timer interrupt
2128 Interrupt failure; transmit; replace card or planar
2129 Interrupt failure; transmit; replace card
2130 Interrupt failure; receive; replace card or planar
2131 Interrupt failure; receive; replace card
2133 Ring indicate stuck on
2134 Receive clock stuck on
2135 transmit clock stuck on
2136 Test indicate stuck on
2137 Ring indicate stuck on
2138 Receive clock not on
2139 Transmit clock not on
2140 Test indicate not on
2141 Data set ready not on
2142 Carrier detect not on
2143 Clear to send not on
2144 Data set ready stuck on
2145 Carrier detect stuck on
2146 Clear to send stuck on
2147 Unexpected transmit interrupt
2148 Unexpected receive interrupt
2150 8251 detected overrun error
2151 Lost data set ready during data wrap
2152 Receive time out during data wrap

Cluster Adapter

Kód Popis
22xx A cluster adapter error has occurred - replace the cluster adapter

Plasma Monitor Adapter

Kód Popis
23xx A plasma adapter display error has occurred - replace the plasma display monitor assembly

Enhanced Graphics Adapter or Video Graphics Adapter

Kód Popis
2401 Video adapter test failure
2402 Video display error
2408 User indicated display attribute test failed
2409 Video display error
2410 Video adapter error; video port error
2416 User indicated character set test failed
2424 User indicated 80 x 25 mode failure
2432 User indicated 40 x 25 mode failure
2440 User indicated mode 320 x 200 mode failure
2448 User indicated 640 x 200 mode failure
2456 User indicated light pen test failure
2464 User indicated paging test failure

Alternate Enhanced Graphics Adapter

Kód Popis
2501 Video adapter test failure
2502 Video display error
2508 User indicated display attribute test failed
2509 Video display error
2510 Video adapter error; video port error
2516 User indicated character set test failed
2524 User indicated 80 x 25 mode failure
2532 User indicated 40 x 25 mode failure
2540 User indicated mode 320 x 200 mode failure
2548 User indicated 640 x 200 mode failure
2556 User indicated light pen test failure
2564 User indicated paging test failure

XT or AT/370 370-M (Memory) and 370-P (Processor) Adapter

Kód Popis
2601 370-M adapter error
2655 370-M adapter error
2657 370-M adapter error
2668 370-M adapter error
2672 370-M adapter error
2673 370-P adapter error
2674 370-P adapter error
2677 370-P adapter error
2680 370-P adapter error
2681 370-M adapter error
2682 370-P adapter error
2694 370-P adapter error
2697 370-P adapter error
2698 XT or AT/370 diagnostic diskette error

XT or AT/370 3277-EM (Emulation) Adapter Error:

Kód Popis
2701 3277-EM adapter error
2702 3277-EM adapter error
2703 3277-EM adapter error

3728/3729 Emulation Adapter or 3270 Connection Adapter

Kód Popis
28xx An emulation adapter fault has occurred - replace the adapter

Color/Graphics Printer

Kód Popis
29xx A general fault has been detected with the printer or it's printer port - replace the adapter

Primary PC Network Adapter

Kód Popis
3001 Network adapter test failure
3002 ROM checksum test failure
3003 Unit ID PROM test failure
3004 RAM test failure
3005 Host interface controller 9HIC) test failure
3006 +/- 12Vdc test failure
3007 Digital loopback test failure
3008 Host detected HIC failure
3009 Sync signal failure and no go bit
3010 HIC test OK and no go bit
3011 Go bit OK, but no command 41
3012 Card not present
3013 Digital failure fall through
3015 Analog failure
3041 Hot carrier on other card
3042 Hot carrier on this card

Secondary PC Network Adapter

Kód Popis
3101 Network adapter test failure
3102 ROM checksum test failure
3103 Unit ID PROM test failure
3104 RAM test failure
3105 Host interface controller 9HIC) test failure
3106 +/- 12Vdc test failure
3107 Digital loopback test failure
3108 Host detected HIC failure
3109 Sync signal failure and no go bit
3110 HIC test OK and no go bit
3111 Go bit OK, but no command 41
3112 Card not present
3113 Digital failure fall through
3115 Analog failure
3141 Hot carrier on other card
3142 Hot carrier on this card

3270 PC/AT Display

Kód Popis
32xx A fault has been detected in the display system - replace the display system

Compact Printer

Kód Popis
33xx A fault has been detected in the printer or printer adapter - replace the printer or printer adapter

Enhanced Display Station Emulation Adapter (EDSEA)

Kód Popis
3504 Adapter connected to twinaxial cable during offline test
3508 Workstation address error
3509 Diagnostic program failure
3540 Workstation address invalid
3588 Adapter address switch error
3599 Diagnostic program failure

General Purpose Interface Bus (GPIB) Adapter

Kód Popis
3601 Adapter test failure
3602 Serial poll mode register write error
3603 Adapter address error
3610 Adapter listen error
3611 Adapter talk error
3612 Adapter control error
3613 Adapter standby error
3614 Adapter asynchronous control error
3615 Adapter asynchronous control error
3616 Adapter error; cannot pass control
3617 Adapter error; cannot address to listen
3618 Adapter error; cannot unaddress to listen
3619 Adapter error; cannot address to talk
3620 Adapter error; cannot unaddress to talk
3621 Adapter error; cannot address to listen with extended addressing
3622 Adapter error; cannot unaddress to listen with extended addressing
3623 Adapter error; cannot address to talk with extended addressing
3624 Adapter error; cannot unaddress to talk with extended addressing
3625 Write to self error
3626 Generate handshake error
3627 Cannot detect Device Clear message error
3628 Cannot detect Selected Device Clear message error
3629 Cannot detect end with end of identify
3630 Cannot detect end of transmission with end of identify
3631 Cannot detect end with 0 bot end of string
3632 Cannot detect end with 7 bit end of string
3633 Cannot detect group execute trigger
3634 Mode 3 addressing error
3635 Cannot recognize undefined command
3636 Cannot detect remote, remote changed, lockout, or lockout changed
3639 Cannot conduct serial poll
3640 Cannot conduct parallel poll
3650 Adapter error; direct memory access (DMA) to 7210
3651 Data error; error on direct memory access (DMA) to 7210
3652 Adapter error; direct memory access (DMA) from 7210
3653 Data error on direct memory access (DMA) from 7210
3658 Uninvoked interrupt received
3659 Cannot interrupt on address status changed
3660 Cannot interrupt on address status changed
3661 Cannot interrupt on command output
3662 Cannot interrupt on data out
3663 Cannot interrupt on data in
3664 Cannot interrupt on error
3665 Cannot interrupt on device clear
3666 Cannot interrupt on end
3667 Cannot interrupt on device execute trigger
3668 Cannot interrupt on address pass through
3669 Cannot interrupt on command pass through
3670 Cannot interrupt on remote changed
3671 Cannot interrupt on lockout changed
3672 Cannot interrupt on service request in
3673 Cannot interrupt on terminal count on direct memory access to 7210
3674 Cannot interrupt on terminal count on direct memory access from 7210
3675 Spurious direct memory access terminal count interrupt
3697 Illegal direct memory access configuration setting detected
3698 Illegal interrupt level setting detected

System Board SCSI Controller

Kód Popis
37xx the system board SCSI controller has failed - replace the motherboard

Data Acquisition Adapter

Kód Popis
3801 Adapter test failure
3810 Timer read test failure
3811 Timer interrupt test failure
3812 Binary input 13 test failure
3813 Binary input 13 test failure
3814 Binary output 14 interrupt request test failure
3815 Binary output 0 count in test failure
3816 Binary input strobe (STB) count out test failure
3817 Binary output 0 clear to send (CTS) test failure
3818 Binary output 1, binary input 0 test failure
3819 Binary output 2, binary input 1 test failure
3820 Binary output 3, binary input 2 test failure
3821 Binary output 4, binary input 3 test failure
3822 Binary output 5, binary input 4 test failure
3823 Binary output 6, binary input 5 test failure
3824 Binary output 7, binary input 6 test failure
3825 Binary output 8, binary input 7 test failure
3826 Binary output 9, binary input 8 test failure
3827 Binary output 10, binary input 9 test failure
3828 Binary output 11, binary input 10 test failure
3829 Binary output 12, binary input 11 test failure
3830 Binary output 13, binary input 12 test failure
3831 Binary output 15, analog input CE test failure
3832 Binary output strobe, binary output GATE test failure
3833 Binary input clear to send, binary output HOLD test failure
3834 Analog input command output (CO), binary input 15 test failure
3835 Counter interrupt test failure
3836 Counter read test failure
3837 Analog output 0 ranges test failure
3838 Analog output 1 ranges test failure
3839 Analog input 0 values test failure
3840 Analog input 1 values test failure
3841 Analog input 2 values test failure
3842 Analog input 3 values test failure
3843 Analog input interrupt test failure
3844 Analog input 23 address or value test failure

Professional Graphics Adapter (PGA)

Kód Popis
3901 PGA test failed
3902 ROM 1 self test failed
3903 ROM 2 self test failed
3904 RAM self test failed
3905 Cold start cycle power error
3906 Data error in communications RAM
3907 Address error in communications RAM
3908 Bad data reading/writing 6845 like register
3909 Bad data in lower E0h bytes reading/writing 6845 like registers
3910 Graphics controller display bank output latches error
3911 Basic clock error
3912 Command control error
3913 Vertical sync scanner error
3914 Horizontal sync scanner error
3915 Intech error
3916 Look up table address error
3917 Look up table red RAM chip error
3918 Look up table green RAM chip error
3919 Look up table blue RAM chip error
3920 Look up table data latch error
3921 Horizontal display error
3922 Vertical display error
3923 Light pen error
3924 Unexpected error
3925 Emulator addressing error
3926 Emulator data latch error
3927 Base for error codes 3928-3930
3928 Emulator RAM error
3929 Emulator RAM error
3930 Emulator RAM error
3931 Emulator horizontal/vertical display problem
3932 Emulator cursor position error
3933 Emulator attribute display problem
3934 Emulator cursor display error
3935 Fundamental emulation RAM problem
3936 Emulation character set problem
3937 Emulation graphics display error
3938 Emulation character display problem
3939 Emulation bank select error
3940 Adapter RAM U2 error
3941 Adapter RAM U4 error
3942 Adapter RAM U6 error
3943 Adapter RAM U8 error
3944 Adapter RAM U10 error
3945 Adapter RAM U1 error
3946 Adapter RAM U3 error
3947 Adapter RAM U5 error
3948 Adapter RAM U7 error
3949 Adapter RAM U9 error
3950 Adapter RAM U12 error
3951 Adapter RAM U14 error
3952 Adapter RAM U16 error
3953 Adapter RAM U18 error
3954 Adapter RAM U20 error
3955 Adapter RAM U11 error
3956 Adapter RAM U13 error
3957 Adapter RAM U15 error
3958 Adapter RAM U17 error
3959 Adapter RAM U19 error
3960 Adapter RAM U22 error
3961 Adapter RAM U24 error
3962 Adapter RAM U26 error
3963 Adapter RAM U28 error
3964 Adapter RAM U30 error
3965 Adapter RAM U21 error
3966 Adapter RAM U23 error
3967 Adapter RAM U25 error
3968 Adapter RAM U27 error
3969 Adapter RAM U29 error
3970 Adapter RAM U32 error
3971 Adapter RAM U34 error
3972 Adapter RAM U36 error
3973 Adapter RAM U38 error
3974 Adapter RAM U40 error
3975 Adapter RAM U31 error
3976 Adapter RAM U33 error
3977 Adapter RAM U35 error
3978 Adapter RAM U37 error
3979 Adapter RAM U39 error
3980 Graphics controller RAM timing error
3981 Graphics controller read/write latch error
3982 Shift register bus output latches error
3983 Addressing error (vertical column of memory; U2 at top)
3984 Addressing error (vertical column of memory; U4 at top)
3985 Addressing error (vertical column of memory; U6 at top)
3986 Addressing error (vertical column of memory; U6 at top)
3987 Addressing error (vertical column of memory; U8 at top)
3988 Addressing error (vertical column of memory; U10 at top)
3989 Horizontal bank latch errors
3990 Horizontal bank latch errors
3991 Horizontal bank latch errors
3992 RAG/CAG graphics controller error
3993 Multiple write modes; nibble mask errors
3994 Row nibble (display RAM) error
3995 Graphics controller addressing error

Display Attachment Unit and 5279 Display

Kód Popis
44xx A fault has occurred with the display system - replace the display system

IEEE 488 (GPIB) Interface Adapter

Kód Popis
45xx A fault has occurred with the GPIB - replace the adapter

ARTIC Multiport/2 Interface Adapter

Kód Popis
4611 ARTIC adapter error
4612/4613 Memory module error
4630 ARTIC adapter error
4640/4641 Memory module error
4650 ARTIC interface cable error

Internal Modem

Kód Popis
48xx The internal modem has failed - replace the modem

Alternate Internal Modem

Kód Popis
49xx The alternate internal modem has failed - replace the alternate internal modem

PC Convertible LCD

Kód Popis
5001 LCD buffer failure
5002 LCD font buffer failure
5003 LCD controller failure
5004 User indicated PEL/drive test failure
5008 User indicated display attribute test failed
5016 User indicated character set test failed
5020 User indicated alternate character set test failure
5024 User indicated 80 x 25 mode test failure
5032 User indicated 40 x 25 mode test failure
5040 User indicated 320 x 200 graphics test failure
5048 User indicated 640 x 200 graphics test failure
5064 User indicated paging test failure

PC Convertible Portable Printer

Kód Popis
5101 Portable printer interface failure
5102 Portable printer busy error
5103 Portable printer paper or ribbon error
5104 Portable printer time out
5105 User indicated print pattern test error

Financial Communication System

Kód Popis
56xx A fault has been detected in the financial communication system - replace the financial communication system

Phoenix BIOS/Chipset Specific

Kód Popis
7000 Chipset CMOS failure
7001 Shadow RAM failure (ROM not shadowed to RAM)
7002 Chipset CMOS configuration data error

Voice Communications Adapter (VCA)

Kód Popis
7101 Adapter test failure
7102 Instruction or external data memory error
7103 PC to VCA interrupt error
7104 Internal data memory error
7105 DMA error
7106 Internal registers error
7107 Interactive shared memory error
7108 VCA to PC interrupt error
7109 DC wrap error
7111 External analog wrap and tone output error
7114 Telephone attachment test failure

3 1/2" Floppy Disk Drive

Kód Popis
7301 Diskette drive/adapter test failure
7306 Diskette change line error
7307 Write protected diskette
7308 drive command error
7310 Diskette initialization failure track 00 error
7311 Drive time out error
7312 NEC drive controller IC error
7313 DMA error
7314 DMA boundary overrun error
7315 Drive index timing error
7316 Drive speed error
7321 Drive seek error
7322 Drive CRC check error
7323 Sector not found error
7324 Address mark error
7325 NEC controller IC seek error

8514/A Display Adapter

Kód Popis
7426 8514 display error
7440 8514/A memory module 31 error
7441 8514/A memory module 30 error
7442 8514/A memory module 29 error
7443 8514/A memory module 28 error
7444 8514/A memory module 22 error
7445 8514/A memory module 21 error
7446 8514/A memory module 18 error
7447 8514/A memory module 17 error
7448 8514/A memory module 32 error
7449 8514/A memory module 14 error
7450 8514/A memory module 13 error
7451 8514/A memory module 12 error
7452 8514/A memory module 06 error
7453 8514/A memory module 05 error
7454 8514/A memory module 02 error
7455 8514/A memory module 01 error
7460 8514/A memory module 16 error
7461 8514/A memory module 27 error
7462 8514/A memory module 26 error
7463 8514/A memory module 25 error
7464 8514/A memory module 24 error
7465 8514/A memory module 23 error
7466 8514/A memory module 20 error
7467 8514/A memory module 19 error
7468 8514/A memory module 15 error
7469 8514/A memory module 11 error
7470 8514/A memory module 10 error
7471 8514/A memory module 09 error
7472 8514/A memory module 08 error
7473 8514/A memory module 07 error
7474 8514/A memory module 04 error
7475 8514/A memory module 03 error

4216 Page Printer Adapter

Kód Popis
7601 Adapter test failure
7602 Adapter card error
7603 Printer error
7604 Printer cable error

PCMCIA Adapter

Kód Popis
8081 Presence test failure (PCMCIA revision number also checksum)
8082 PCMCIA register test failure

PS/2 Speech Adapter

Kód Popis
84xx A fault has occurred with the speech adapter - replace the speech adapter

2MB XMA Memory Adapter

Kód Popis
85xx A fault has occurred with the memory module - replace the memory module

PS/2 Pointing Device

Kód Popis
8601 Pointing device: mouse time out error
8602 Pointing device: mouse interface error
8603 System board: mouse interrupt error
8604 Pointing device or system board error
8611 System bus error
8612 TrackPoint II error
8613 System bus or TrackPoint II error

MIDI Interface

Kód Popis
89xx A fault has occurred with the MIDI adapter - replace the MIDI adapter

3363 Worm Optical Drive/Adapter

Kód Popis
91xx A fault has occurred in the drive or adapter - replace the adapter or the drive

SCSI Adapter (W/32 bit Cache):

Kód Popis
96xx A fault has occurred with the SCSI adapter - replace the SCSI adapter

Multiprotocol Adapter

Kód Popis
10001 Presence test failure
10002 Card selected feedback error
10003 Port 102h register test failure
10004 Port 103h register test failure
10006 Serial option cannot be disabled
10007 Cable error
10008 IRQ 3 error
10009 IRQ 4 error
10010 UART register failure
10011 Internal wrap test of UART control line failed
10012 External wrap test of UART control line failed
10013 UART transmit error
10014 UART receive error
10015 UART receive error - data not equal to transmit data
10016 UART interrupt error
10017 UART baud rate test failure
10018 UART receive external wrap test failure
10019 UART FIFO buffer failure
10026 8255 port A error
10027 8255 port B error
10028 8255 port C error
10029 8254 timer 0 error
10030 8254 timer 1 error
10031 8254 timer 2 error
10032 Bi-sync data set ready (DSR) response error
10033 Bi-sync clear to send(CTS) error
10034 8251 hardware reset test failed
10035 8251 function generator
10036 8251 status error
10037 Bi-sync timer interrupt error
10038 Bi-sync transmit interrupt error
10039 Bi-sync receive interrupt error
10040 Stray IRQ 3 error
10041 Stray IRQ 4 error
10042 Bi-sync external wrap error
10044 Bi-sync data wrap error
10045 Bi-sync line status error
10046 Bi-sync time out error during wrap test
10050 8273 command acceptance or time out error
10051 8273 port A error
10052 8273 port B error
10053 SDLC modem status logic error
10054 SDLC timer IRQ 4 error
10055 SDLC IRQ 4 error
10056 SDLC external wrap error
10057 SDLC interrupt results error
10058 SDLC data wrap error
10059 SDLC transmit interrupt error
10060 SDLC receive interrupt error
10061 DMA channel 1 transmit error
10062 DMA channel 1 receive error
10063 8273 status detect failure
10064 8273 error detect failure

Internal 300/1200Bps Modem

Kód Popis
10101 Presence detect failure
10102 Card selected feedback error
10103 Port 102h register test error
10106 Serial option cannot be disabled
10108 IRQ 3 error
10109 IRQ 4 error
10110 UART chip register failure
10111 UART control line internal wrap test failure
10113 UART transmit error
10114 UART receive error
10115 UART error - transmit and receive data not equal
10116 UART interrupt function error
10117 UART baud rate test failure
10118 UART interrupt driven receive external data wrap test failure
10125 Modem reset result code error
10126 Modem general result code error
10127 Modem S registers read/write error
10128 Modem echo on/off error
10129 Modem enable/disable result codes error
10130 Modem enable number/word result codes error
10133 Connect results for 300 baud not received
10134 Connect results for 1200 baud not received
10135 Modem fails local analog loopback 300 baud test
10136 Modem fails local analog loopback 1200 baud test
10137 Modem does not respond to escape/reset sequence
10138 S register 13 shows incorrect parity or number of data bits
10139 S register 15 shows incorrect bit rate

ESDI or MCA IDE Fixed Disk or Adapter

Kód Popis
10450 Read/write test failed
10451 read verify test failed
10452 Seek test failed
10453 Wrong drive type indicated
10454 Controller sector buffer test failure
10455 Controller invalid failure
10456 Controller diagnostic command failure
10461 Drive format error
10462 Controller head select error
10463 Drive read/write sector error
10464 Drive primary detect map unreadable
10465 Controller: error-correction code (ECC) 8 bit error
10466 Controller: error correction code (ECC) 9 bit error
10467 Drive soft seek error
10468 Drive head seek error
10469 Drive soft error count exceeded
10470 Controller attachment diagnostic error
10471 Controller wrap mode interface error
10472 Controller wrap mode drive select error
10473 Read verify test errors
10480 Seek failure: drive 0
10481 Seek failure: drive 1
10482 Controller transfer acknowledge error
10483 Controller reset failure
10484 Controller: head select 3 error
10485 Controller: head select 2 error
10486 Controller: head select 1 error
10487 Controller: head select 0 error
10488 Controller: read gate - command complete 2 error
10489 Controller: write gate - command complete 1 error
10490 Diagnostic area read error: drive 0
10491 Diagnostic area read error: drive 1
10492 Controller error, drive 1
10493 Reset error, drive 1
10499 Controller failure

5 1/4 External Disk Drive or Adapter

Kód Popis
107xx A fault has occurred with the external disk drive or adapter - replace the disk drive or adapter

SCSI Adapter (16 bit without Cache)

Kód Popis
112xx A fault has occurred with the SCSI adapter - replace the SCSI adapter

System Board SCSI Adapter

Kód Popis
113xx A fault has occurred with the system board SCSI adapter - replace the motherboard

Processor Complex

Kód Popis
129005 DMA error
12901 Processor board: processor test failure
12902 Processor board: cache test failure
12904 Second level cache failure
12905 Cache enable/disable errors
12907 Cache fatal error
12908 Cache POST program error
12912x Hardware failure
12913x Micro channel bus time out
12914x Software failure
12915x Processor complex error
12916x Processor complex error
12917x Processor complex error
12918x Processor complex error
12919x Processor complex error
12940x Processor complex failure
12950x Processor complex failure
129900 Processor complex serial number mismatch

P70/P75 Plasma Display and Adapter

Kód Popis
14901 Plasma display adapter failure
14902 Plasma display adapter failure
14922 Plasma display failure
14932 External display device failure

XGA Display Adapter

Kód Popis
152xx A fault has occurred with the XGA display adapter - replace the display adapter

120MB Internal Tape Drive

Kód Popis
164xx A fault has occurred with the internal tape drive - replace the tape drive

6157 Streaming Tape Drive

Kód Popis
16520 Streaming tape drive failure
16540 Tape attachment adapter failure

Primary Token Ring Network Adapter

Kód Popis
166xx A fault has occurred with the network adapter - replace the network adapter

Alternate Token Ring Network Adapter

Kód Popis
167xx A fault has occurred with the network adapter - replace the network adapter

PS/2 Wizard Adapter

Kód Popis
18001 Interrupt controller failure
18002 Incorrect timer count
18003 Timer interrupt failure
18004 Sync check interrupt failure
18005 Parity check interrupt failure
18006 Access error interrupt failure
18012 Bad checksum error
18013 Micro Channel interface error
18021 Wizard memory compare or parity error
18022 Wizard memory address line error
18023 Dynamic RAM controller error
18029 Wizard memory byte enable error
18031 Wizard memory expansion module memory compare or parity error
18032 Wizard memory expansion module byte enable error
19039 Wizard memory expansion module byte enable error

DBCS Japanese Display Adapter

Kód Popis
185xx A fault has occurred with the display adapter - replace the display adapter

80286 Memory Expansion Option Module

Kód Popis
194xx A fault has occurred with the memory module - replace the memory module

Image Adapter

Kód Popis
200xx A fault has occurred with the image adapter - replace the image adapter

Unknown SCSI Device

Kód Popis
208xx A fault has occurred in an unknown SCSI adapter - replace the unknown SCSI adapter

SCSI Removable Media

Kód Popis
209xx A fault has occurred in the SCSI removable disk - replace the removable disk

SCSI Fixed Disk

Kód Popis
210PLSC "PLSC" codes indicate errors
  P = SCSI ID number (Physical Unit Number or PUN)
  L = Logical unit number (LUN, usually 0)
  S = Host adapter slot number
  C = SCSI drive capacity
  A = 60MB
  B = 80MB
  C = 120MB
  D = 160MB
  E = 320MB
  F = 400MB
  H = 1.02MB (1GB)
  I = 104MB
  J = 212MB
  U = Undetermined or non IBM OEM drive

SCSI Tape Drive

Kód Popis
211xx A fault has occurred with the SCSI tape drive - replace the SCSI tape drive

SCSI Printer

Kód Popis
212xx A fault has occurred with the SCSI printer - replace the SCSI printer

SCSI Processor

Kód Popis
213xx A fault has occurred with the SCSI adapter processor - replace the SCSI adapter

SCSI Write Once Read Multiple (WORM) Drive

Kód Popis
214xx A fault has occurred with the SCSI WORM drive - replace the SCSI WORM drive

SCSI CD-ROM Drive

Kód Popis
215xx A fault has occurred with the SCSI CD-ROM drive - replace the SCSI CD-ROM drive

SCSI Scanner

Kód Popis
216xx A fault has occurred with the SCSI Scanner - replace the SCSI Scanner

SCSI Magneto Optical Drive

Kód Popis
217xx A fault has occurred with the SCSI Magneto Optical Drive - replace the drive

SCSI Jukebox Changer

Kód Popis
218xx A fault has occurred with the SCSI Jukebox Changer - replace the device

SCSI Communications

Kód Popis
219xx A fault has occurred with the SCSI Communications device - replace the device

XGA-2 Adapter

Kód Popis
243xxxx A fault has occurred with the XGA-2 adapter - replace the adapter

Dynamic Configuration Select (DCS) Information kódy

Kód Popis
I998001x Bad integrity of DCS master boot record
I988002x Read failure of DCS master boot record
I988003x DCS master boot record is not compatible with the planar ID
I988004x DCS master boot record is not compatible with the model/submodel byte
I988005x Bad integrity of CMOS/NVRAM or internal process error
I988006x Read failure of header/mask/configuration record
I988007x Bad integrity of header/mask/configuration record
I988008x Hard disk does not support the command to set the maximum RBA
I988009x DCS master boot record is older than system ROM
I9880402 Copyright notice in E000 segment does not match the one in DCS MBR
I9880403 DCS MBR is not compatible with the system board ID or model/submodel byte

Initial Microcode Load (IML)

Kód Popis
I999001x Invalid disk IML error
I999002x Disk IML record load error
I999003x Disk IML record incompatible with system board
I999004x Disk IML record incompatible with processor/processor card
I999005x Disk IML not attempted
I999006x Disk stage II system image load error
I999007x Disk stage II image checksum error
I999008x IML not supported on primary disk drive
I999009x Disk IML record is older than ROM
I99900x1 Invalid diskette IML record
I99900x2 Diskette IML record load error
I99900x3 Diskette IML record incompatible with system board
I99900x4 Diskette IML record incompatible with processor board
I99900x5 Diskette IML recovery prevented (valid password and CE override not set)
I99900x6 Diskette stage II image load error
I99900x7 Diskette stage II image checksum error
I99900x9 Diskette IML record older then ROM

No Bootable Device, Initial Program Load (IPL)

Kód Popis
I9990301 Hard disk error
I9990302 Invalid disk boot record, unable to read IPL boot record from disk
I9990303 IML system partition boot failure
I9990304 No bootable device with ASCII console
I9990305 No bootable device
I9990306 Invalid SCSI Device boot record
I9990401 Unauthorized access (manufacturing boot request with valid password)
I9990402 Missing ROM IBM copyright notice
I9990403 IML Boot record incompatible with system board/processor card

 

Microid Research/Mr. BIOS

Chyba

Popis
Lock Check Check if a system lock-byte is set and wait for user response if an error is generated.  Check the panel lock or circuitry
Numlock/Password/Setup Set Numlock on (if set) and ask for password (if set) and display setup message
Typematic Rate Set the typematic rate
Floppy Disk Perform any further initialization needed
Hard Disk Perform any further initialization needed
Video Mode Set primary video mode and display any errors found during initialization routines
Shadow and Cache Enable The shadow RAM and cache are enabled
Adapter ROM Initialize adapters with a ROM signature of 55AA.  Self tests will be performed by the equipment concerned before handing back control to the POST
Video Monitor Mode Set the video mode based on the information in the CMOS and update the time variables from the RTC
Parity/NMI Enable Enable NMI by setting bit 7 of CMOS address 41 and enable parity.  There should be no failures during this
Set Stack Set the last significant byte of the stack pointer and install the shadow RAM at E000 if set by CMOS
Acknowledge Acknowledge errors and set primary video mode before calling Int 19 bootloader.  Errors reported will await a keyboard repines before proceeding.  Errors beyond this point are normally software related

 

Phoenix BIOS
 
Phoenix BIOS Text Error hlįsenia
 

Hlįsenie

Popis
Diskette drive A error Drive A: is present but fails the POST diskette tests.  Check that the drive is defined with the proper diskette type in Setup and that the disk is installed correctly
Extended RAM failed at offset: nnn Extended memory not working or not configured properly at offset: nnn
Failing Bits: nnnn The hexadecimal number nnnn is a map of the bits at the RAM address that failed the memory test.  Each 1 in the map indicates a failed bit
Fixed Disk 0 Failure Fixed disk is not working or not configured properly.  Check to see if fixed disk is installed properly.  Run Setup to be sure the fixed disk type is correctly identified
Fixed Disk 1 Failure Fixed disk is not working or not configured properly.  Check to see if fixed disk is installed properly.  Run Setup to be sure the fixed disk type is correctly identified
Fixed Disk Controller Failure Fixed disk is not working or not configured properly.  Check to see if fixed disk is installed properly.  Run Setup to be sure the fixed disk type is correctly identified
Incorrect Drive A: type - run Setup Type of diskette for drive A: not correctly identified in Setup
Invalid NVRAM media type Problem with NVRAM (CMOS) access
Keyboard controller error The keyboard controller failed test.   Try replacing the keyboard
Keyboard error Keyboard not working
Keyboard error nn BIOS discovered a stuck key and displays the scan code nn for the stuck key
Keyboard locked - Unlock key switch Unlock the system to proceed
Monitor type does not match CMOS - Run Setup Monitor type not correctly identified in Setup
Operating system not found Operating system cannot be located on either A: or C:.  Enter Setup and see if fixed disk and drive A: are properly identified
Parity Check 1 Parity error found in the system bus.   BIOS attempts to locate the address and display it on screen.  If it cannot locate the address, it displays ???
Parity Check 2 Parity error found in the I/O bus.   BIOS attempts to locate the address and display it on screen.  If it cannot locate the address, it displays ???
Press <F1> to resume, <F2> to Setup Displayed after any recoverable error message.  Press F1 to start the boot process or F2 to enter Setup and change any settings
Real-time clock error Real-time clock fails BIOS test.   Might require motherboard repair
Shadow RAM failed at offset: nnnn Shadow RAM failed at offset nnnn of the 64KB block at which the error was detected
System battery is dead - Replace and run Setup The CMOS clock battery indicator shows the battery is dead.  Replace the battery and run Setup to reconfigure the system
System cache error - Cache disabled RAM cache failed the BIOS test.   BIOS disabled the cache
System CMOS checksum bad - run Setup System CMOS RAM has been corrupted or modified incorrectly.  Perhaps by an application program that changes data stored in CMOS.  Run Setup and reconfigure the system either by getting the default values or making your own selections
System RAM failed at offset: nnnn System RAM failed at offset nnnn of the 64KB block at which the error was detected
System timer error The timer test failed.  Requires repair of system motherboard